Bone resorption during the first year after implantation of a single-segment dynamic interspinous stabilization device and its risk factors

نویسندگان

  • Kaifeng Wang
  • Zhenqi Zhu
  • Bo Wang
  • Yi Zhu
  • Haiying Liu
چکیده

BACKGROUND Dynamic interspinous stabilization devices generally provide satisfactory results, but can result in recurrent lumbar disc herniation, spinous process fracture, or bone resorption of the spinous process. The purpose of this study was to investigate if the Wallis dynamic stabilization device is associated with bone resorption. METHODS Patients who underwent single-segment posterior lumbar decompression and implantation of a Wallis dynamic interspinous stabilization device at the L4/5 level between January 1, 2009 and October 1, 2011 were included. Bone resorption rate, Oswestry Disability Index (ODI), Japanese Orthopedic Association (JOA) score, and visual analogue scale (VAS) pain score were measured. Patient baseline and 1-year follow-up data were collected and analyzed. The bone resorption rate of the L4 and L5 spinous processes was calculated. RESULTS Twenty four males and 20 females with a mean age of 42.7 ± 14.7 years were included. Twenty nine patients had significant bone resorption (bone resorption rate > 20%) and 15 had no bone resorption (bone resorption rate ≤ 20%) at 1 year after surgery. Lumbar lordosis ≥ 50° was associated with a lower bone resorption than lumbar lordosis < 50° and increasing BMI was associated with increased bone resorption. There were no significant differences between the bone resorption and no bone resorption groups in the improvement rate of VAS pain score, ODI, and JOA score at 1 year after surgery. CONCLUSIONS Significant bone resorption occurs within 1 year after implantation of the Wallis device in more than 50% of patients. However, it does not affect short-term functional results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Interspinous Spacer: A New Posterior Dynamic Stabilization Concept for Prevention of Adjacent Segment Disease

Introduction. Posterior Dynamic stabilization using the interspinous spacer device is a known to be used as an alternative to rigid fusion in neurogenic claudication patients in the absence of macro instability. Actually, it plays an important in the management of adjacent segment disease in previously fused lumbar spine. Materials and Method. We report our experience with posterior dynamic sta...

متن کامل

Fusion after interspinous device placement.

Lumbar interspinous devices are intended to unload the facet joints, restore foraminal height, lower intradisk pressure, and provide motion-preserving stabilization. They are an alternative treatment for patients with spinal degeneration and have increased in popularity in recent years. To the authors' knowledge, heterotopic ossification has not been previously reported around an interspinous d...

متن کامل

Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case

We present here a rare case of heterotopic ossification in interspinous/interlaminar Coflex device. The classical surgical indications for these implants are degenerative canal stenosis, discogenic low back pain, disk herniations, facet syndrome, and instability. However, fractures of spinous processes are a potential risk after interspinous/interlaminar devices' implantation. Recently, heterot...

متن کامل

Avascular necrosis of vertebral body with fracture of unilateral posterior facet at the level of insertion of interspinous device

This report shows a rare case of avascular necrosis of vertebra body after insertion of interspinous device after insertion of interspinous device and its plausible cause. A 82-year-old woman presented with severe back pain for 1 week without injury. In her history, she had undergone decompression and implantation of L4-5 interspinous device for the relief of neurogenic claudication at 4 year a...

متن کامل

clinical and radiographic methods of marginal bone loss evaluation after immediate implantation in post-extraction sockets.

Introduction: To achieve the best esthetic and functional results of implantation and patient satisfaction, different protocols of implant therapy have been recommended. Immediate implantation can provide the outcome faster than other protocols making it the treatment of choice. The rate of peri-implant bone resorption should be measured clinically and radiographically as bone support is a key ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015