Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial.
نویسندگان
چکیده
Automated cell counters are widely used in modern clinical laboratories to provide reliable, fast, and cost-effective complete blood counts (CBCs), white blood cell differentials, and reticulocyte measurements. In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a variety of body fluids. Bayer recently introduced the ADVIA 2120 system as an automation-ready cell counter for mid- to high-volume testing in the clinical laboratory. This instrument, which builds on the established technology of the ADVIA 120 system, operates with a cyanide-free method for hemoglobin measurement, has a new user interface, and can routinely analyze biological fluid samples in addition to blood. We used 749 samples from 6 worldwide trial sites to evaluate the clinical performance of this new device. Accuracy of the ADVIA 2120 system versus its predecessor model, the ADVIA 120 system, was excellent for all CBC and white cell differential parameters and reticulocyte counts (all correlation coefficients except for basophils >0.9). Correlation of the white cell differential with the standard manual method and within-run precision of the ADVIA 2120 system also was very good. Use of the novel cyanide-free method for hemoglobin measurement had no clinically significant impact on hemoglobin results, even in patients with hemoglobinopathies. We concluded that the ADVIA 2120 system has clinically equivalent performance to the ADVIA 120 system.
منابع مشابه
The Clinical Significance of Schistocytes: A Prospective Evaluation of the International Council for Standardization in Hematology Schistocyte Guidelines
OBJECTIVE The presence of ≥1% schistocytes on a peripheral blood smear (PBS) is an important criterion for the diagnosis of thrombotic microangiopathy (TMA). The reporting of schistocytes has been standardized by the International Council for Standardization in Hematology (ICSH). Despite the availability of guidelines, however, the assessment of schistocytes remains subjective. More recently, t...
متن کاملAnemia in a dog
Laboratory findings A blood sample was submitted by mail to the Clinical Pathology Laboratory, University Animal Hospital, Swedish University of Agricultural Sciences, Uppsala, Sweden, for a complete hematological profile. The hematology analysis was performed on an Advia 2120 hematology instrument (Siemens Healthcare Diagnostics, Erlangen, Germany) and by evaluation of a May‐Grünwald Giemsa st...
متن کاملEffects of yeast on automated cell counting.
We studied the effects of yeast in peripheral blood samples on results reported by an ADVIA 120/2120 Hematology System (Bayer HealthCare, Diagnostics Division, Tarrytown, NY). In a simulated candidemia model, very high concentrations (1-5 x 10(8) colony-forming units [CFU]/mL) of Candida glabrata and Candida parapsilosis caused a spuriously elevated platelet count. No such effect was observed w...
متن کاملFeline Differential Leukocyte Count with ProCyte Dx: Frequency and Severity of a Neutrophil‐Lymphocyte Error and How to Avoid It
BACKGROUND Erroneous neutrophil and lymphocyte counts from analysis of feline blood samples were transferred directly into the hospital information system from the ProCyte Dx hematology instrument in our after-hours laboratory. Errors usually were not detected by the users. HYPOTHESIS/OBJECTIVES To quantify the frequency and severity of errors associated with the ProCyte Dx analyzer and to id...
متن کاملReference Intervals for Platelet Parameters in Korean Adults Using ADVIA 2120
Analysis of thrombopoiesis is important in evaluating hematologic and non-hematologic diseases. Recent improvements in automated blood cell analyzers allow measurement of several platelet parameters, providing additional information on the underlying mechanisms of thrombocytosis and thrombocytopenia. The ADVIA 2120 Hematology System (Siemens AG, Eschborn, Germany) distinguishes platelets by a t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Laboratory hematology : official publication of the International Society for Laboratory Hematology
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2005