Improved Fat Suppression With High Resolution Balanced Steady State Imaging in the Breast

نویسندگان

  • D. B. Engel
  • C. J. Moran
  • F. Kelcz
  • S. O. Schoenberg
چکیده

(a) because of the variable level of fat suppression. Both 3DPR-SSFP with WC-SSFP (b) and IDEAL 3DPR-SSFP (c) provide a more consistent level of fat suppression allowing for better delineation of fine fibroglandular structure. IDEAL 3DPR-SSFP (c) also resolves fat-water swap due to B0 inhomogeneity in superior region of the breast. Red arrows: Note tiny gap in fibroglandular tissue in WC SSFP (see text) Improved Fat Suppression With High Resolution Balanced Steady State Imaging in the Breast

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrafast near-isotropic spatial resolution 3D balanced-SSFP Dixon imaging in the breast

INTRODUCTION: T2 imaging in the breast is most commonly performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence. The in-plane spatial resolution is high (<1mm) but the 3-4 mm slice thickness blurs fine structures and makes multi-planar reformatting sub-optimal. Balanced steady-state free precession (b-SSFP) techniques yield high SNR images in short scan times with a T2-like (T2/...

متن کامل

Coronary artery imaging at 3T using a novel ECG gated SSFP-Dixon sequence and a motion insensitive view ordering scheme

Purpose: MR Coronary Artery Imaging (CAI) remains challenging due to the need for high spatial resolution as well as due to constraints imposed by physiological motion and the stringent requirements for fat and muscle suppression to visualize the arterial signal with good contrast. 3D ECG gated balanced steady state free precession (SSFP) imaging has shown great promise due to its high SNR, exc...

متن کامل

Breast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE

INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...

متن کامل

Spectrally selective imaging with wideband balanced steady-state free precession MRI.

PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balance...

متن کامل

Multiple Acquisition Fat-Saturated Balanced Steady State Free Precession Imaging

INTRODUCTION While balanced-SSFP (bSSFP) imaging is advantageous in its ability to produce high SNR in short imaging times, its clinical application has been limited due to several well-known shortcomings. The bright signal from fat is typically unwanted, and the short repetition times (TRs) required to avoid banding artifacts lead to limitations in the achievable resolution. This is especially...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009