Procedural Outcome and One Year Follow up of Patients Undergoing Endovascular Stenting for Coarctation of Aorta: A Single Center Study
نویسندگان
چکیده
INTRODUCTION Coarctation of aorta is the fourth most common cardiac lesion requiring intervention. While surgery used to be the only treatment option, endovascular intervention is now considered the first option in simple coarctation lesions. Despite increased popularity, there are currently no FDA approved stents for use in coarctation of aorta and data on the outcome of this procedure is still sparse. METHODS Between October 2004 and June 2010, 33 patients who underwent treatment with Cheatham-Platinum stents for coarctation of aorta were retrospectively studied. All the patients underwent control CT scans at 6 month and echocardiography at 1 year follow-up. RESULTS There were 17 females and 16 males with a mean age of 26.64 ± 16.30 years (range 2-71 years). The mean stent length and balloon diameter were 3.18 ± 0.56 mm and 15.7 ± 3.12 mm respectively. We achieved an immediate success rate of 96.9% with the only complication of aortic rupture which led to our single mortality in this series. At 6 month follow up no complications were noted in the CT scans. The mean echocardiographic aortic arch gradient at one year follow up was 21.73 ± 11.06 mmHg. CONCLUSION This study is one of the few cohorts of patients with stenting for coarctation of aorta in Iranian population which comprised a diverse group of patients from early childhood to elderly. It was demonstrated in this study that stenting for coarctation of aorta is a safe and effective procedure if done carefully and performed in selected patients.
منابع مشابه
نتایج فوری و میانمدت استفاده از استنت در درمان کوارکتاسیون آئورت در کودکان و نوجوانان
Background: Coarctation of aorta is narrowing of proximal descending aorta. Interventional procedures such as balloon angioplasty & stent implantation has been progressively in use as alternatives for surgery in increasing number of children with diagnosis of coarctation of aorta. The aim of this study was to evaluate the use of endovascular stent in children with coarctation of aorta. Methods...
متن کاملImmediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting
Background Aortic Coarcatation (CoA) is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs). Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA). We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty wi...
متن کاملDual Arterial Access for Stenting of Aortic Coarctation in Patients with Near-Total Descending Aortic Interruption
Endovascular stenting is a recognized treatment strategy for the treatment of coarctation of aorta (COA) in adults. The aortic coarctation is usually crossed retrogradely from the descending aorta via the femoral approach. We report three patients who had near-total descending aortic interruption and underwent successful stenting of severe COA using a combined radial/brachial and femoral approa...
متن کاملComparison between covered and bare Cheatham-Platinum stents for endovascular treatment of patients with native post-ductal aortic coarctation: immediate and intermediate-term results.
OBJECTIVES This study sought to evaluate the outcomes of endovascular treatment with covered versus bare Cheatham-platinum stents (NuMed, Hopkinton, New York) in coarctation of aorta (CoA) patients. BACKGROUND Covered stenting has been newly recognized as a useful therapeutic method for patients with native CoA, but there has been no study comparing the use of covered stents with bare stents ...
متن کاملEvaluation of Exercise-Induced Hypertension Post Endovascular Stenting of Coarctation of Aorta
BACKGROUND Coarctation of the aorta (COA) is a defect that accounts for 5-8% of all congenital heart diseases. Balloon angioplasty as a treatment for COA is increasingly performed, with endovascular stents having been proposed as a means of improving the efficacy and safety of the procedure. The aim of this study was to evaluate the systolic blood pressure gradient at rest and during maximal ex...
متن کامل