Strongly Balanced Four Bowtie Systems

نویسندگان

  • Mario Gionfriddo
  • Salvatore Milici
چکیده

A k-bowtie is the graph consisting of two cycles of lenght k, having exactly one vertex in common. A k-bowtie system of order v is a pair (X,B), where X is a finite set of v vertices and B is a collection of edge disjoint k-bowties (called blocks) which partitions the edge set of the complete graph Kn, defined in X. In this paper we study 4-bowtie systems. We determine the spectrum of all types of balanced 4-bowtie systems. Mathematics Subject Classification: 05B05

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Balanced Quatrefoil Decomposition of Complete Multigraphs

Definition. Let Kn denote the complete graph of n vertices. The complete multigraph λKn is the complete graph Kn in which every edge is taken λ times. The t-foil (or the t-windmill) is a graph of t edge-disjoint K3’s with a common vertex and the common vertex is called the center of the t-foil. In particular, the 2-foil, the 3-foil, and the 4-foil are called the bowtie, the trefoil, and the qua...

متن کامل

Dynamic Bowtie Filter for Cone-Beam/Multi-Slice CT

A pre-patient attenuator ("bowtie filter" or "bowtie") is used to modulate an incoming x-ray beam as a function of the angle of the x-ray with respect to a patient to balance the photon flux on a detector array. While the current dynamic bowtie design is focused on fan-beam geometry, in this study we propose a methodology for dynamic bowtie design in multi-slice/cone-beam geometry. The proposed...

متن کامل

Kite systems of order 8; embedding of kite systems into bowtie systems

This article consist of two parts. In the first part, we enumerate the kite systems of order 8; in the second part, we consider embedding kite systems into bowtie systems.

متن کامل

The influence of the bow tie filtration on the dose and image quality for the Elekta XVI coneBeam CT

Introduction Cone Beam Computer Tomography (CBCT) is used to control the position of the patient based on internal body structures. Thereby, the CBCT data set is fitted to the planning CT image. The accuracy of this alignment process strongly depends on the quality of the CBCT images. The radiotherapy department of the cantonal hospital St.Gallen operates two Elekta Synergy linacs equipped with...

متن کامل

A TLD based method to estimate bowtie filter shape in PET/CT

Background: In CT systems, the machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. The shape of this bowtie filter is complicated and its geometry is often not available in detail. These renders the CT dose index (CTDI) to have different values in measurement versus Monte Carlo simulation studies and other analytical calculations especially in dosimetry of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014