Are the site and mode of termination matters of prime importance in catheter ablation of persistent atrial fibrillation?
نویسنده
چکیده
Role of AF Termination: Is There Any Difference Between Direct to Sinus Rhythm Versus Via Atrial Tachycardia? During catheter ablation of persistent atrial fibrillation (AF), the arrhythmia often organizes into a regular atrial tachyarrhythmia (AT) or directly terminates to sinus rhythm (SR). The termination of AF during ablation may be associated with higher long-term maintenance of SR, and has been proposed as an endpoint;1–4 however, there are also conflicting results5–7 and the effect of regular rhythms occurring during ablation on the clinical outcome is as yet unclear. AF termination cannot be achieved in all patients using current techniques. Some patients without AF termination with ablation do well clinically without arrhythmia recurrence and some patients with AF termination develop later recurrence of AT and/or AF. AF termination in patients with persistent AF can be achieved usually at the cost of extensive ablation, procedural risks, longer procedural and ablation times, and increased risk of post-ablation AT. Recently, I found increasing evidence that AF termination during catheter ablation is associated with a better clinical outcome, especially in patients with longstanding persistent AF. However, it is currently unclear how to identify those who will not terminate with ablation and those who do not have any potential to restore SR or who will not terminate with ablation, but ultimately do well clinically.
منابع مشابه
Impact of atrial fibrillation termination site and termination mode in catheter ablation on arrhythmia recurrence.
BACKGROUND Although atrial fibrillation (AF) termination has been reported as a predictor of clinical outcome after persistent AF (PsAF) ablation, the relationship between AF termination site and mode and clinical outcome has not been fully evaluated. METHODS AND RESULTS A total of 135 patients (62±9 years) underwent their first ablation procedure for PsAF (76 longstanding PsAF). With an endp...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملNon-Inducibility Or Termination As Endpoints Of Atrial Fibrillation Ablation: What Is The Role?
Catheter ablation is widely used to treat drug-refractory, symptomatic atrial fibrillation (AF). However, beyond pulmonary vein isolation, there remains little consensus on the recommended approach to ablation both in paroxysmal or persistent AF patients. Although ancillary ablation strategies are often used, the lack of a clear endpoint for AF ablation makes it challenging to evaluate their im...
متن کاملA systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia
Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system. Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 78 1 شماره
صفحات -
تاریخ انتشار 2014