Adaptation of blank-corrected methods for measurement of total and conjugated bilirubin and uric acid to the centrifugal analyzer.

نویسندگان

  • R E Cross
  • M G Heintges
  • J Savory
  • P W Wentz
چکیده

The blank-corrected determination in serum of total and conjugated bilirubin and of uric acid has been adapted to the centrifugal analyzer. Bilirubin is measured by a modified Jendrassik and Grof procedure; uric acid is determined kinetically by using a reaction based on reduction of ferric ion, including a uricase-treated blank. Sensitivity and precision of both methods are excellent, and results compare well with those obtained by commonly used procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New kinetic procedure for the measurement of conjugated bilirubin with a centrifugal analyzer.

A procedure has been developed for the automated measurement of conjugated bilirubin in serum with a centrifugal analyzer. The conjugated bilirubin is measured by a fixed time kinetic method which monitors the reaction between conjugated bilirubin and diazotized sulfanilic acid at 550 nm. Results are calculated based on a comparison of the reagent blank-corrected absorbance changes between 15 s...

متن کامل

Enzyme-coupled measurement of uric acid in serum with a centrifugal analyzer.

An early-reading blank-corrected end-point determination of uric acid in serum has been developed for use with a centrifugal analyzer. The method is based on a modification of the uricase (urate:oxygen oxidoreductase, EC 1.7.3.3)/catalase (hydrogen peroxide:hydrogen peroxide oxidoreductase EC 1.11.1.6)/aldehyde dehydrogenase (aldehyde:NAD(P)+ oxidoreductase, EC 1.2.1.5)-coupled analytical schem...

متن کامل

Evaluation of the Beckman creatinine analyzer.

We compared results obtained with the Beckman Creatinine Analyzer (Beckman Instruments, Inc.) to those with the GEMSAEC Centrifugal Analyzer (Electro-Nucleonics, Inc.) and with a manual method for determination of creatinine in serum and urine. Linearity, stability, recovery, and precision were evaluated. Interference from bilirubin, protein, lipemia, uric acid, and hemolysis is negligible, but...

متن کامل

Crocin Bleaching Assay Using Purified Di-gentiobiosyl Crocin (a-crocin) from Iranian Saffron

Objective(s) Crocin bleaching assay (CBA) is a new method for determination of antioxidant capacity. In CBA, addition of hydrogen to the conjugated double bonds of crocin results in reduction of crocin and increase in the absorbance at 440 nm, which is considered as a measure of antioxidant potential. Here CBA method was set up using di-gentiobiosyl crocin or a-crocin from Iranian saffron. The...

متن کامل

Centrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.

We describe two centrifugal analyzer methods for measuring total bilirubin in serum. Diazotized 2-chloroaniline-5-sulfonic acid is used in both. In the first procedure, ethylene glycol and methanol are used as an accelerator solvent; results correlate well with those by a Jendrassik and Grof method adapted to the centrifugal analyzer, but there is considerable hemolysis interference. In the sec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 1976