Clinical experience with intracranial brain needle biopsy using frameless surgical navigation.

نویسندگان

  • I M Germano
  • J V Queenan
چکیده

Interactive, image-guided frameless systems are currently used in many centers for navigation during open craniotomies. We report our experience in 34 cases of brain needle biopsy performed with a frameless stereotactic system based on an optical digitizer. Preoperative images were acquired after adhesive skin markers were placed on the patient's head. Biopsy planning was done on the computer monitor using triplanar and 3-dimensional reformatted images. All biopsies were performed under local anesthesia through a twist drill craniostomy. The biopsy guide consisted of a rigid canula stabilized by a self-retaining retractor arm attached to the reference arc placed around the patient's head in the operating room. The position of the probe tip and its ideal continuation were displayed on real-time reformatted images and compared with the previously obtained trajectory plan. The position of the probe was adjusted as necessary to align it accurately with the surgical trajectory calculated by the computer in angles and displayed on the computer images. Diagnostic tissue was obtained in all cases; the mean and standard deviation of the maximum longitudinal diameter of the lesions was 3.5 +/- 1.1 cm. All patients reported minimal discomfort during the procedure; there was no operative morbidity or mortality. Our experience suggests that interactive image-guided frameless stereotactic brain needle biopsy successfully provides diagnostic tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical use of the optical digitizer for intracranial neuronavigation.

OBJECTIVE Computer-assisted frameless navigation techniques are used in many centers for intracranial neurosurgical procedures. In this study, we assessed the accuracy and the clinical usefulness of a frameless system based on the optical digitizer in a variety of intracranial procedures. METHODS The optical digitizer (StealthStation, Sofamor Danek, Memphis, TN) was used to perform 170 neuros...

متن کامل

Principles of Neuronavigation

Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...

متن کامل

Frameless Stereotactic Biopsy of Intracranial Lesions: Evaluation of Efficacy and Complications

Objective: Frameless stereotactic biopsy has been shown in multiple studies to be a safe and effective procedure for the diagnosis of brain lesion. In this study the authors will evaluate the safety of the procedure and associated complications including neurological deficits in our set up of developing countries. Methods: Forty two patients with different brain lesions were biopsied using fram...

متن کامل

Management strategies after nondiagnostic results with frameless stereotactic needle biopsy: Retrospective review of 28 patients

BACKGROUND Although frameless stereotactic needle biopsy is an accepted procedure for the diagnosis of intracranial lesions, findings are nondiagnostic in 2-15% of patients and no recommendations yet exist to guide subsequent care. After reviewing the postoperative course after nondiagnostic biopsy of 28 patients, we developed a paradigm to guide management in the future. METHODS In reviewing...

متن کامل

The advantages of frameless stereotactic biopsy over frame-based biopsy.

A comparison study is presented, which examines the outcome, complications and cost of stereotactic brain biopsy performed with a frameless versus a frame-based method. The technique of frameless stereotactic biopsy has been shown previously, in both laboratory and in vivo studies, to achieve a level of accuracy at least equal to frame-based biopsy. The investigators have validated the techniqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer aided surgery : official journal of the International Society for Computer Aided Surgery

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 1998