Flow time through esophagogastric junction derived during high-resolution impedance-manometry studies: a novel parameter for assessing esophageal bolus transit.

نویسندگان

  • Zhiyue Lin
  • Hala Imam
  • Frèdèric Nicodème
  • Dustin A Carlson
  • Chen-Yuan Lin
  • Brandon Yim
  • Peter J Kahrilas
  • John E Pandolfino
چکیده

This study aimed to develop and validate a method to measure bolus flow time (BFT) through the esophagogastric junction (EGJ) using a high-resolution impedance-manometry (HRIM) sleeve. Ten healthy subjects were studied with concurrent HRIM and videofluoroscopy; another 15 controls were studied with HRIM alone. HRIM studies were performed using a 4.2-mm-outer diameter assembly with 36 pressure sensors at 1-cm intervals and 18 impedance segments at 2-cm intervals (Given Imaging, Los Angeles, CA). HRIM and fluoroscopic data from four barium swallows, two in the supine and two in the upright position, were analyzed to create a customized MATLAB program to calculate BFT using a HRIM sleeve comprising three sensors positioned at the crural diaphragm. Bolus transit through the EGJ measured during blinded review of fluoroscopy was almost identical to BFT calculated with the HRIM sleeve, with the nadir impedance deflection point used as the signature of bolus presence. Good correlation existed between videofluoroscopy for measurement of upper sphincter relaxation to beginning of flow [R = 0.97, P < 0.001 (supine) and R = 0.77, P < 0.01 (upright)] and time to end of flow [R = 0.95, P < 0.001 (supine) and R = 0.82, P < 0.01 (upright)]. The medians and interquartile ranges (IQR) of flow time though the EGJ in 15 healthy subjects calculated using the virtual sleeve were 3.5 s (IQR 2.3-3.9 s) in the supine position and 3.2 s (IQR 2.3-3.6 s) in the upright position. BFT is a new metric that provides important information about bolus transit through the EGJ. An assessment of BFT will determine when the EGJ is open and will also provide a useful method to accurately assess trans-EGJ pressure gradients during flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manometric and demographic predictors of incomplete bolus transit in patients diagnosed with ineffective esophageal motility

Background neffective esophageal motility (IEM), or frequent failed peristalsis in the Chicago Classification, is a common motility abnormality describing a non-specific manometric pattern of peristaltic failure. With the addition of multichannel intraluminal impedance technology to high resolution esophageal manometry (HRM), evaluation of bolus transit simultaneously with esophageal contractio...

متن کامل

The four phases of esophageal bolus transit defined by high-resolution impedance manometry and fluoroscopy.

We aimed to model esophageal bolus transit based on esophageal pressure topography (EPT) landmarks, concurrent intrabolus pressure (IBP), and esophageal diameter as defined with fluoroscopy. Ten healthy subjects were studied with high-resolution impedance manometry and videofluoroscopy. Data from four 5-ml barium swallows (2 upright, 2 supine) in each subject were analyzed. EPT landmarks were u...

متن کامل

Sleeve sensor versus high-resolution manometry for the detection of transient lower esophageal sphincter relaxations.

Transient lower esophageal sphincter relaxations (TLESRs) are the most important mechanism by which gastroesophageal reflux occurs, and sleeve sensor manometry is the gold standard for detection of TLESRs. The aim of this study was to evaluate manometry with closely spaced sideholes (high-resolution manometry) for the detection of TLESRs as an alternative. In 12 patients with gastroesophageal r...

متن کامل

A new mechanism of gastroesophageal reflux in hiatal hernia documented by high-resolution impedance manometry: a case report

Gastroesophageal reflux disease (GERD) is recognized to be a multifactorial disease and several mechanisms leading to reflux have been described, nevertheless its pathophysiology has not been fully clarified. Hiatus hernia is a known risk factor for GERD since it impairs the esophagogastric junction, leading to: reduction in lower esophageal sphincter pressure; increase in the frequency of the ...

متن کامل

Utilizing Intrabolus Pressure and Esophagogastric Junction Pressure to Predict Transit in Patients With Dysphagia

BACKGROUND/AIMS High-resolution manometry (HRM), with a greatly increased number of recording sites and decreased spacing between sites, allows evaluation of the dynamic simultaneous relationship between intrabolus pressure (IBP) and esophagogastric junction (EGJ) relaxation pressure. We hypothesized that bolus transit may occur when IBP overcomes integrated relaxation pressure (IRP) and analyz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Gastrointestinal and liver physiology

دوره 307 2  شماره 

صفحات  -

تاریخ انتشار 2014