Coil therapy for patients with severe emphysema and bilateral incomplete fissures – effectiveness and complications after 1-year follow-up: a single-center experience

نویسندگان

  • Konstantina Kontogianni
  • Vasiliki Gerovasili
  • Daniela Gompelmann
  • Maren Schuhmann
  • Hans Hoffmann
  • Claus Peter Heussel
  • Felix JF Herth
  • Ralf Eberhardt
چکیده

BACKGROUND Lung volume reduction coil (LVRC) treatment is established in daily endoscopic lung volume reduction routine. The aim of this study was to evaluate the safety and efficacy of LVRC treatment. PATIENTS AND METHODS This was a retrospective analysis of 86 patients (male/female: 40/46, mean age: 64±7 years) with severe COPD and bilateral incomplete fissures. A total of 10 coils were unilaterally implanted in a single lobe, and 28 out of 86 patients were treated bilaterally. At 90-, 180-, and 365-day follow-up, changes in pulmonary function test (PFT), 6-minute walk test (6MWT) and modified Medical Research Council (mMRC) dyspnea scale, as well as possible complications, were recorded. RESULTS At 90 days, the forced expiratory volume in 1 second did improve (P<0.001), but the improvement was not sustained at the 180- and 365-day follow-up (baseline: 0.71±0.21 vs 0.77±0.23 vs 0.73±0.22 vs 0.70±0.18 L). Both vital capacity and residual volume improved significantly (P<0.001) at the 90- and 180-day follow-up, but the improvement was lost after 365 days. Total lung capacity decreased at the 90-day follow-up but returned to baseline values at the 180- and 365-day follow-up. 6MWT (P=0.01) and mMRC (P=0.007) also improved at 90 and 180 days (Δ6MWT of 31±54 and 20±60 m, respectively), but the improvement was also lost at the 365-day follow-up. No significant further improvement was evident at any point in the follow-up after the second procedure. A total of 4 out of 86 patients passed away due to complications. Significant complications in the first 3 months and then at 12 months included the following: severe hemoptysis in 4 (3.5%) and 4 (3.5%) patients, pneumonia requiring hospitalization in 32 (28.1%) and 9 (7.9%) patients and pneumothorax in 7 (6.1%) and 2 (1.7%) patients, respectively. Milder adverse events included self-limited hemoptysis, pneumonias, or COPD exacerbations treated orally. CONCLUSION LVRC improved PFT, 6MWT and mMRC initially, but the improvement was lost after 365 days. Furthermore, we observed 4 deaths and significant severe complications, which need to be further elucidated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of endobronchial coil treatment for lung volume reduction in patients with severe heterogeneous emphysema and bilateral incomplete fissures: a six-month follow-up.

BACKGROUND Treatment with lung volume reduction coils (LVRC) may be effective in patients with severe heterogeneous emphysema and incomplete fissures. OBJECTIVE We hypothesized that LVRC placement improves pulmonary function, exercise tolerance and quality of life in these patients. METHODS Twenty-six patients with chronic obstructive pulmonary disease (COPD), 13 males and 13 females, aged ...

متن کامل

Short Term Outcome of Antenatal Hydronephrosis: A Single Center Experience

Background Fetal hydronephrosis is a common urinary tract anomaly that may result in renal parenchyma damage. Ultrasound is considered a simple, noninvasive procedure to diagnose and track antenatal hydronephrosis. Our aim was to study the clinical course of fetal hydronephrosis in fetuses. Materials and Methods</...

متن کامل

پنوموتوراکس و پنوموپریتوئن به‌دنبال تراکئوستومی

Aim and Background: Percutaneous tracheostomy, a common surgical procedure in the field of otolaryngology, is associated with complications, such as bleeding, infection, subcutaneous emphysema, pneumothorax, recurrent laryngeal nerve injury and tracheal ring fracture. However, the incidence of pneumothorax and pneumoperitoneum in a single individual is rare.  Case report: A 70-year-old woman wa...

متن کامل

گزارش یک مورد غیرمعمول سمیت ناشی از مصرف میزان کم متوتروکسات: گزارش موردی

Background: Standard treatment of Gestational Trophoblastic Disease (GTD) is chemotherapy. Single-agent chemotherapy regime including Methotrexate (MTX) or Actinomycin. Single-agent is widely used in treatment of persistent trophoblastic disease. We reported an uncommon toxicity of low-dose single-agent methotrexate in a patient. Case Presentation: A 20-year-old woman, primary gravid after two ...

متن کامل

Long-term follow-up after bronchoscopic lung volume reduction treatment with coils in patients with severe emphysema

BACKGROUND AND OBJECTIVE Bronchoscopic lung volume reduction coil (LVR-coil) treatment has been shown to be safe and clinically effective in patients with severe emphysema in the short term; however, long-term safety and effectiveness has not been evaluated. The aim of this study was to investigate the long-term safety and effectiveness of LVR-coil treatment in patients with severe emphysema. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017