Influence of building maintenance, environmental factors, and seasons on airborne contaminants of swine confinement buildings.

نویسندگان

  • C Duchaine
  • Y Grimard
  • Y Cormier
چکیده

Eight swine confinement buildings, selected to cover the widest possible range of cleanliness, were visited twice during winter and once during summer to verify the range, seasonal variations, and correlations between biological and chemical contaminants. Physical aspects were graded for dirtiness (1 = clean, 10 = dirty), ventilation, air temperature, number of animals, building, and room size. Air samples were taken to measure relative humidity, CO2, ammonia, total dust, and microbiological counts and/or identification (bacteria and molds); endotoxin levels also were measured. During winter, average measurements and ranges were: CO2 = 0.304% (0.254 to 0.349%); ammonia = 19.6 ppm (1.9 to 25.9 ppm); dust = 3.54 mg/m3 (2.15 to 5.60 mg/m3). There were 883 cfu/m3 (547 to 2862 cfu/m3) of molds, 4.25 x 10(5) cfu/m3 (1.67 x 10(5) to 9.30 x 10(5) cfu/m3) of total bacteria, 29 cfu/m3 (3 to 94 cfu/m3) of thermophilic actinomycetes). A significant decrease in bacterial levels (p = 0.04), dust (p = 0.0008), ammonia (p = 0.005), and CO2 (p < 0.0001) was observed during summer sampling when compared with winter levels. Mold counts were positively correlated (p = 0.03) with dirtiness scores, while bacterial counts were negatively correlated with this parameter (p < 0.002), whereas bacteria and endotoxins were correlated with the number of animals (p < 0.05). Ambient gases (CO2 and ammonia) correlated with each other (p = 0.006). Bacteria were the most important contaminant in swine confinement buildings, and endotoxin levels found were also very high (mean = 4.9 x 10(3) EU/m3). We conclude that a wide range of air contamination exists in swine confinement buildings of different maintenance. There is a decrease in some of these contaminants during summer. Observed dirtiness of the swine confinement buildings has a poor predictive value concerning air quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Swine confinement buildings: effects of airborne particles and settled dust on airway smooth muscles.

Swine confinement workers are exposed to various contaminants. These agents can cause airway inflammation and bronchoconstriction. This study was undertaken to evaluate if the bronchoconstrictive effects of swine barn air and settled dust are mediated by endotoxin, and if these effects are directly mediated on airway smooth muscles. Mouse tracheas where isolated and mounted isometrically in org...

متن کامل

Short term exposure to low amounts of airway irritants in a swine confinement building and inflammatory markers in blood and exhaled air.

INTRODUCTION AND OBJECTIVE Swine confinement buildings are known to contain large concentrations of airway irritants, and a number of studies have shown acute inflammatory effects in previously unexposed subjects when introduced to the environment in such buildings. However, studies comparing different methods of assessing such reactions are lacking, and it is not known if a measurable response...

متن کامل

Temporal variation of indoor air quality in an enclosed swine confinement building.

Human health hazards can exist in swine confinement buildings due to poor indoor air quality (IAQ). During this study, airborne dust and ammonia concentrations were monitored within a working farrowing facility as indicators of IAQ. The purposes of this study were to assess the temporal variability of the airborne dust and ammonia levels over both a daily and seasonal basis, and to determine th...

متن کامل

Temporal and spatial distributions of aerial contaminants in an enclosed pig building in winter.

Optimal management of indoor air quality in an enclosed swine house, especially in winter, is indispensable for preventing the transmission of infectious respiratory disease to workers and animals. Studies are needed to elucidate the correlation of aerial contaminants and climate factors. It was observed that indoor air contamination in an enclosed pig building was the highest at 2:00--5:00 PM,...

متن کامل

Evaluation of environmental comfort parameters of workspace in industrial buildings1(Case Study: typical control building of combined cycle power plants)

Due to the superiority of functional requirements of equipment and systems over human requirements in the field of architectural and environmental design of industrial buildings, users have to adapt themselves to the conditions which might be followed by imposed biological and psychological pressures. The present study examines the components and environmental parameters influenced by building ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AIHAJ : a journal for the science of occupational and environmental health and safety

دوره 61 1  شماره 

صفحات  -

تاریخ انتشار 2000