A Study of Tissue Vibration Transmissibility Using a Scanning Laser Vibrometer
نویسندگان
چکیده
Prolonged exposure to vibration has been associated with the development of handarm vibration syndrome (HAVS). While vibration is known to have adverse physiological effects on the tissues of the human hand, it is still unclear how these physiological effects are influenced by factors such as tissue thickness or vibration intensity, frequency, and duration. Understanding the response of the hand to vibration may be helpful in determining the mechanisms behind the development of HAVS. Dynamic response of the hand and arm to vibration has been studied by several investigators (Abrams and Suggs, 1966, Burstrom, 1990). However, these studies have concentrated on the overall impedance of the hand/arm system or have looked only at the vibration transmitted along the bones or on the surface of the hand or arm. The vibration transmissibility through individual tissues such as skin, fat, muscle, blood vessels, and nerves has not been investigated because of the difficulty in making these measurements in vivo. Computer models of the hand have been proposed as a solution to this problem. By using finite element modeling techniques, each tissue can be modeled separately and the vibration transmissibility at different tissue depths can be calculated. However, for these models to be truly useful, validation is necessary. As a first approximation to validate these models, transmissibility in skeletal muscle and fat was measured as a function of the tissue depth using a scanning Doppler laser vibrometer. METHODS
منابع مشابه
Measurement of hand-vibration transmissibility by non-contact measurement techniques
Background: Workers who use hand-held vibrating tools may experience finger blanching attacks due to episodic vasospasm in the digital vessels. In occupational medicine, the pathological consequences to the exposure to handtransmitted vibration are known as vibration induced white finger (VWF). In many cases, workers are recommended to use anti-vibration gloves and a standard procedure (ISO 108...
متن کاملIntegrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design
This research integrated a MEMS electrostatic driven micro-probe and a laser Doppler vibrometer for non-contact vibration mode scanning probe microscope system design. The microprobe tip was placed in perpendicular to the sample surface, and the built-in capacitor on the microprobe was excited to vibrate by a sinusoidal drive voltage to generate Coulomb electrostatic force. The applied frequenc...
متن کاملBroadband Vibration Measurements Using a Continuously Scanning Laser Vibrometer
In this article we will apply the continuously scanning vibrometer measurement principle introduced in literature for stepped sine measurementsto broadband excitations. Special attention will be given to the errors which are introduced in the procedure. Also, a method will be proposed to estimate the complexity of the vibration patterns. Different scanning signals to cover the measured area of ...
متن کاملNon-contact measurement of facial surface vibration patterns during singing by scanning laser Doppler vibrometer
This paper presents a method of measuring the vibration patterns on facial surfaces by using a scanning laser Doppler vibrometer (LDV). The surfaces of the face, neck, and body vibrate during phonation and, according to Titze (2001), these vibrations occur when aerodynamic energy is efficiently converted into acoustic energy at the glottis. A vocalist's vibration velocity patterns may therefore...
متن کاملA biomechanical modeling of an automotive passenger body to investigate the vertical vibration in various road profiles using transmissibility analysis
In the current paper, a biomechanical model of human body with unique structure is developed for evaluating the biodynamic responses, the vibration transmissibility and the transmitted accelerations to vertical vibration for the seated position with ignoring backrest support. In this regard, the 6-DoF Lumped-parameter model with six concentrated masses which are connected with linear springs an...
متن کامل