Development of an Investigation Method for Evaluation of Microbiological Indoor Air Quality

نویسندگان

  • S Sampò
  • S Bonetta
  • S Mosso
  • E Carraro
چکیده

An investigation method to evaluate microbiological air quality has been developed; it involved a compiling building inspections checklist and occupants questionnaires, choosing sites, sampling frequency and analysis procedures. This method has been applied in a representative building with HVAC system and open-space offices. Air samples and microclimate parameters were collected at the same time. Airborne microorganisms levels ranged from 50 CFU⋅m to 500 CFU⋅m. A high fungal concentration (>1000 CFU⋅m) was found associated with a winter flood event. Statistical analysis showed a significant seasonal and daily variation of airborne microorganisms. Staphylococcus and Micrococcus were the most common bacterial genera and Penicillium was the most widespread fungal genus. Samples collected at HVAC system levels demonstrated an overall good microbiological removal efficiency of the device, except for unusual events (flood). This study highlights the importance, for air quality control, of a preventive approach based on microbiological risk analysis and critical point control. INDEX TERMS Bioaerosols, HVAC, airborne bacteria, airborne fungi, health effects INTRODUCTION Indoor air quality is becoming an increasingly important issue for occupational and public health (Clarke and Nikkel, 1995). Health effects related to indoor air microbiological quality have increased, with a tendency to some energy saving measures provided for buildings such as tightly sealing, air recirculation and introduction of HVAC (Heating Ventilation Air Conditioning) (Nathanson, 1995). In addition, ageing population, the increasing number of sensitive individuals and a tendency to spend more time indoors (90% of their time) further worsen this problem (Seltzer, 1995). HVAC modifies air quality and can affect indoor microorganisms concentration (Parat, Perdrix, Fricker-Hidalgo, et al., 1997). Airborne microorganisms may be responsible for specific infections, Building Related Illnesses (Legionellaire’s disease, aspergillosis, hypersensivity pneumonitis, etc.) and can be involved in Sick Building Syndrome (Stetzenbach, 1997). * Contact author email: [email protected] Proceedings: Indoor Air 2002

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls' High Schools in Arak, Iran)

As s‌tudents spend one-third of their time at school, their health, comfort, and productivity are mos‌tly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and s‌tudents aren't allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comf...

متن کامل

Indoor air quality monitoring in urban areas using Smart Sensing Technology

Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...

متن کامل

Natural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations

The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...

متن کامل

بررسی ارتباط بین غلظت ذرات معلق در هوای داخل بیمارستان کودکان تهران و هوای آزاد اطراف آن در سال 1386

Background and Objectives: In recent years exposure to fine airborne particles has been identified as an important factor affecting human health. Epidemiological studies have showed that the aerosol laden air can be an agent for microorganisms’ dispersion. Ignoring internal sources, ambient air quality significantly affects indoor air quality. Since people spend most of their times in the indoo...

متن کامل

Investigation on the Comfort Evaluation Index Cpd of Indoor Environments

Based on the factors that influence the indoor comfort situation, a new index Comprehensive Percentage Dissatisfied CPD is proposed, which depends on the thermal factor, noise and indoor air quality. The calculation formulas in CPD are described in this paper and a method called gradation analysis is used to deduce the values of each coefficient in CPD. Finally, the index CPD is used to evaluat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002