Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method
نویسندگان
چکیده
This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The linearity was established over the concentration range of 5-50 m g mL-1 for LSV and 0.5-20 m g mL-1 for HPLC method. The intra- and inter-day relative standard deviation (RSD) was less than 3.96 and 3.07% for LSV and HPLC, respectively. Limits of quantification were determined as 5.0 and 0.50 m g mL-1 for LSV and HPLC, respectively. No interference was found from tablet excipients at the selected assay conditions. The methods were applied for the quality control of commercial fulvestrant dosage form to quantify the drug and to check the formulation content uniformity.
منابع مشابه
Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method
This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...
متن کاملStability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method
This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کامل