Standardized x-tonometers.

نویسنده

  • C R JACKSON
چکیده

STANDARDIZED Schi6tz tonometers of the original (weighted) type have been on sale in the United States for more than 10 years, and a considerable amount of information has been collected which bears out the acceptability of the current specification. This knowledge was assembled in the First Decennial Report of the Committee on Standardization of Tonometers (1954). Following the American lead, standardized tonometers have been introduced into the United Kingdom, and the work of the W. H. Ross Foundation (Scotland) in this field has already been described (Jackson, 1953, 1955). The specification for the weighted model of the Schiotz tonometer is now internationally accepted, as is the new conversion of scale readings into mm. Hg (Schi6tz) intra-ocular pressure. The instrument manufacturers, both in the U.K. and U.S.A., now submit their products to independent testing stations 'for examination and, if satisfactory, for certification as standard tonometers. These measures have at least introduced a considerable degree of uniformity between different tonometers, but it still has to be remembered that this type of tonometer is not without its own sources of instrumental error, which have been assessed by Friedenwald (1937), and that we must add to these the variables introduced by different observers, by the degree of relaxation of the patient, and his position, and by the time of day. I believe that the tendency to read a Schi6tz tonometer to a degree of accuracy closer than the whole scale division is a mistaken one, and that the current calibration charts, which suggest a value for the various scale readings accurate to fractions of a millimetre of mercury, imply a standard of accuracy which is entirely misleading. Some years after the introduction of his original tonometer, Schiotz (1927) described his tonometer with a convex plunger. This is what we know as the X-tonometer, and is without the additional weights which were used in the original model to adjust the instrument to cover the various ranges of intra-ocular pressure. The different shape of the plunger-end enables a wide range of intra-ocular pressures to be registered without the need to alter the weight acting on the plunger. In the United States, the X-tonometer attracts very little interest. In the United Kingdom and in Scandinavia, on the other hand, the weightless model is very popular, and its sales greatly outnumber those of the weighted model. From a study of Schiotz's original description of the weightless tonometer, together with the work of the American Committee, a specification has been

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence of Calibration Errors in Goldmann Applanation Tonometers

PURPOSE To determine the prevalence of calibration errors in Goldmann applanation tonometers at Farabi Eye Hospital. METHODS This cross-sectional study was performed on all tonometers in use at Farabi Eye Hospital. All Haag-Streit Goldmann applanation tonometers were checked according to the manufacturer's method by two independent observers and by a third observer in case of mismatched resul...

متن کامل

Tonometer calibration in Brasília, Brazil.

PURPOSE To determine calibration errors of Goldmann applanation tonometers in ophthalmic clinics of Brasília, Brazil, and correlate the findings with variables related to tonometers model and utilization. METHODS Tonometers from ophthalmic clinics in Brasília, Brazil, were checked for calibration errors. A standard Goldmann applanation tonometer checking tool was used to asses the calibration...

متن کامل

Schiötz tonometers. An assessment of their usefulness.

THERE is no doubt that applanation tonometry gives more accurate information about the level of intra-ocular pressure than does indentation tonometry. This increased accuracy is due to the fact that applanation readings approach very closely to the levels of pressure in the undisturbed eye (Po), owing to the small volume of fluid displaced by the application of the tonometer (Goldmann, 1957). A...

متن کامل

Comparison of Perkins, Tono-Pen and Schiøtz tonometers in paediatric patients under general anaesthesia.

This cross-sectional study aimed to investigate if the Tono-Pen, Schiøtz and Perkins tonometers could be used interchangeably in general practice for measuring elevated intraocular pressure. A total of 74 eyes of 37 paediatric patients under general anaesthesia were checked with all 3 tonometers. All of the tonometers gave significantly different measurements from each other. However, with a me...

متن کامل

A New Method for the Automatic Testing of Applanation Tonometers

Abstract: The exact measurement of the intraocular pressure is of great diagnostic importance in the field of ophthalmology. According to the international standard DIN EN ISO 8612, the tonometers being used are subject to strict type approval and, furthermore, must be checked on a regular basis. For calibration of one of the most widely used and most precise tonometers known as applanation ton...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 1959