Schematic eye models for simulation of patient visual performance.

نویسندگان

  • J B Doshi
  • E J Sarver
  • R A Applegate
چکیده

PURPOSE To determine if model eyes can simulate the visual performance of normal human eyes under conditions of varying low myopic blur, pupil size, and contrast. METHODS High and low contrast Bailey-Lovie logMAR visual acuity (VA) of three normal eyes of three subjects were measured for four artificial pupil sizes and ten levels of myopic defocus. Simulated visual acuities were then determined for three model eyes--the Indiana Eye with no spherical aberration, the Indiana Eye with average spherical aberration, and the Kooijman Eye--by generating optically aberrated VA charts for each testing condition using Visual Optics Lab software by Sarver and Associates, Inc, and having the subjects read high resolution printouts of these charts using a 3-mm pupil and optimal spectacle correction. The correlation between real VA and simulated VA was then plotted and a regression line calculated. RESULTS Slopes for the Indiana Eye, Indiana Eye with spherical aberration, and Kooijman Eye were 0.98, 0.98, and 1.01 for high contrast, and 0.92, 0.67, and 0.75 for low contrast, respectively. The r2 values were 0.73, 0.74, and 0.77, for high contrast, and 0.69, 0.40, and 0.50 for low contrast, respectively. Under low contrast conditions the Indiana Eye VA was significantly closer to the real VA than that of the other two models (P<.0003). CONCLUSION Visual performance can be simulated by eye models. The simple single surface Indiana Eye with no spherical aberration best modeled both high and low contrast visual acuity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

Realistic Simulation of Peripheral Vision Using An Aspherical Eye Model

A novel method is proposed to accurately simulate the peripheral vision under different visual perception. An accurate aspherical schematic eye model is firstly introduced to reasonably predict the anatomical and optical properties of the human eye. This eye model is composed of the Navarro schematic eye model with aspherical surfaces as a basic model, and a corresponding accommodation model, a...

متن کامل

The Relationship Between Self-Management and Quality of Life and Visual Function in Glaucoma Patients

Introduction: Self-management positively contributes to the Quality of Life of many patients with chronic diseases. Objective: The present study aimed to investigate the relationship between self-management and the quality of life and visual performance among patients with glaucoma. Materials and Methods: The current cross-sectional and comparative study was conducted at the...

متن کامل

P58: Visual Working Memory Performance Based on Saccades in Children with and without Specific Learning Disorder: An Eye-Tracking Study

Some of the previous studies show that children with SLD have deficits in visual processing and working memory. Hence, the aim of this research was to investigate problems of visual working memory based on behavioral neuroscience method, using an eye tracker device. The method of present study was ex-post facto study. The participants included couple of twelve children with SLD (mean age=10.92)...

متن کامل

Emergency department resource optimisation for improved performance: a review

Emergency departments (EDs) have been becoming increasingly congested due to the combined impacts of growing demand, access block and increased clinical capability of the EDs. This congestion has known to have adverse impacts on the performance of the healthcare services. Attempts to overcome with this challenge have focussed largely on the demand management and the application of system wide p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2001