Influence of macromolecule baseline on 1H MR spectroscopic imaging reproducibility
نویسندگان
چکیده
PURPOSE Poorly characterized macromolecular (MM) and baseline artefacts are known to reduce metabolite quantitation accuracy in 1 H MR spectroscopic imaging (MRSI). Increasing echo time (TE) and improvements in MM analysis schemes have both been proposed as strategies to improve metabolite measurement reliability. In this study, the influence of TE and two MM analysis schemes on MRSI reproducibility are investigated. METHODS An experimentally acquired baseline was collected using an inversion recovery sequence (TI = 750 ms) and incorporated into the analysis method. Intrasubject reproducibility of MRSI scans, acquired at 3 Tesla, was assessed using metabolite coefficients of variance (COVs) for both experimentally acquired and simulated MM analysis schemes. In addition, the reproducibility of TE = 35 ms, 80 ms, and 144 ms was evaluated. RESULTS TE = 80 ms was the most reproducible for singlet metabolites with COVs < 6% for total N-acetyl-aspartate, total creatine, and total choline; however, moderate multiplet dephasing was observed. Analysis incorporating the experimental baseline achieved higher Glu and Glx reproducibility at TE = 35 ms, and showed improvements over the simulated baseline, with higher efficacy for poorer data. CONCLUSION Overall, TE = 80 ms yielded the most reproducible singlet metabolite estimates. However, combined use of a short TE sequence and the experimental baseline may be preferred as a compromise between accuracy, multiplet dephasing, and T2 bias on metabolite estimates. Magn Reson Med 77:34-43, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
منابع مشابه
Reproducibility of quantitative cerebral T2 relaxometry, diffusion tensor imaging, and 1H magnetic resonance spectroscopy at 3.0 Tesla.
OBJECTIVES The reproducibility of quantitative cerebral T2 relaxometry, diffusion tensor imaging, and H magnetic resonance (MR) spectroscopic imaging was assessed on a clinical 3.0 T MR system. MATERIALS AND METHODS Repeated measurements in 10 healthy volunteers were used to establish the reproducibility of quantitative measures derived from different quantitative MR techniques, namely the T2...
متن کاملFeasibility and Reproducibility of Echo Planar Spectroscopic Imaging on the Quantification of Hepatic Fat
OBJECTIVES 1H-MRS is widely regarded as the most accurate noninvasive method to quantify hepatic fat content (HFC). When practical period of breath holding, and acquisition of HFC over multiple liver areas is considered, a fast MR spectroscopic imaging technique is desired. The aim of this study is to examine the feasibility and reproducibility of echo planar spectroscopic imaging (EPSI) on the...
متن کاملReproducibility of brain metabolite concentration measurements in lesion free white matter at 1.5 T
BACKGROUND Post processing for brain spectra has a great influence on the fit quality of individual spectra, as well as on the reproducibility of results from comparable spectra. This investigation used pairs of spectra, identical in system parameters, position and time assumed to differ only in noise. The metabolite amplitudes of fitted time domain spectroscopic data were tested on reproducibi...
متن کاملReproducibility of 3D 1H MR spectroscopic imaging of the prostate at 1.5T.
PURPOSE To determine the reproducibility of 3D proton magnetic resonance spectroscopic imaging ((1)H-MRSI) of the human prostate in a multicenter setting at 1.5T. MATERIALS AND METHODS Fourteen subjects were measured twice with 3D point-resolved spectroscopy (PRESS) (1)H-MRSI using an endorectal coil. MRSI voxels were selected in the peripheral zone and combined central gland at the same loca...
متن کاملReproducibility of proton MR spectroscopic imaging findings.
PURPOSE To study the intraindividual, interindividual, and intraregional reproducibility of multisection proton MR spectroscopic imaging in healthy adults. METHODS Six subjects were studied three times with proton MR spectroscopic imaging. Multisection long-echo-time proton MR spectroscopic imaging permits simultaneous acquisition of N-acetylaspartate (NAA), choline-containing compounds (Cho)...
متن کامل