چکیده
PURPOSE To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). MATERIALS AND METHODS Clinical data from 25 eyes of 14 patients (age range, 52-77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (P(IOLadj)) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (n(kadj)) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELP(adj)). P(IOLadj) was compared to the real IOL power implanted (P(IOLReal), calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. RESULTS No statistically significant differences were found between P(IOLReal) and P(IOLadj) when ELP(adj) was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, P(IOLReal) was significantly higher when compared to P(IOLadj) without using ELP(adj) and also compared to the values estimated by the other formulas. CONCLUSIONS Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملError induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.
AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previo...
متن کاملPrediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملThe Camellin - Calossi formula
Nowadays is well stated that after keratorefractive surgery, without a special correction, the intraocular lens (IOL) power is usually inaccurate. The article by Kenneth J. Hoffer1 which appeared in the first JanuaryMarch 2010 issue of the Journal of Emmetropia is an excellent review of recently published studies that analyze and try to solve the problems to calculate IOL power in eyes with pri...
متن کاملEstimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography
PURPOSE To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in patients who have undergone corneal refractive surgery. METHODS This study included 23 patients (30 eyes) who have undergone myopic corneal refractive surgery and subseq...