A Study on Relationship Between the Heat Release of Later-age Concrete and the Concrete Strength Development
نویسندگان
چکیده
The adiabatic temperature rise of early-age concrete can be precisely tested by the device. However, the insufficient accuracy of testing device can lead to inaccurate measurements of adiabatic temperature rise of later-age concrete. The purpose of this paper is to create a model to predict the hydration heat of later-age concrete. Based on the previous studies, it is known that the heat release of the concrete is accomplished with the increment of the concrete strength and concrete strength can be accurately measured. Thus, a preliminary later-age hydration heat model was established. The correction of the model was verified through experiments.
منابع مشابه
Laboratory study of mechanical properties of ordinary concrete under high heat consumption in hydraulic structures, along with validation by SEM and XRD tests
In this laboratory research, a mixing plan was made of ordinary concrete containing Portland cement type 2 with a grade of 500 kg / m3. Compressive strength, tensile strength and modulus of elasticity tests of concrete were performed on concrete samples at 90 days of processing age at 21 °C and 600 ° C. In order to further evaluate and validate the results, SEM and XRD tests were performed on c...
متن کاملOn the Relation of Setting and Early-Age Strength Development to Porosity and Hydration in Cement-Based Materials.
Previous research has demonstrated a linear relationship between compressive strength (mortar cubes and concrete cylinders) and cumulative heat release normalized per unit volume of (mixing) water for a wide variety of cement-based mixtures at ages of 1 d and beyond. This paper utilizes concurrent ultrasonic reflection and calorimetry measurements to further explore this relationship from the t...
متن کاملRELATIONSHIP OF TENSILE STRENGTH OF STEEL FIBER REINFORCED CONCRETE BASED ON GENETIC PROGRAMMING
Estimating mechanical properties of concrete before designing reinforced concrete structures is among the design requirements. Steel fibers have a considerable effect on the mechanical properties of reinforced concrete, particularly its tensile strength. So far, numerous studies have been done to estimate the relationship between tensile strength of steel fiber reinforced concrete (SFRC) and ot...
متن کاملEffect of Impressed Current on Bond Strength Between Steel Rebar and Concrete
The deterioration of bond strength between reinforcing steel and concrete as a result of impressed cathodic current with respect to the exposure time was investigated. A current in the magnitude of 3ma/ft2 (based on reinforcing rebar area) was used for a period of five years. Chemical analyses for sodium (Na+), potassium (K+) and chloride (Cl-) ions in concrete cylinders were performed as a fun...
متن کاملExperimental investigation of the strength of glass fiber-reinforced concrete exposed to high temperature
This study investigated the effects of high temperature exposure on the compressive, tensile, and flexural strengths of concrete containing glass fiber. A total of 108 cubic specimens (150 mm × 150 mm × 150 mm), cylindrical specimens (300 mm × 150 mm), and prismatic specimens (500 mm × 150 mm × 150 mm) were prepared for compressive, tensile, and flexural strength testing, respectively. The spec...
متن کامل