DPPH·-luminol chemiluminescence system and its application in the determination of scutellarin in pharmaceutical injections and rat plasma with flow injection analysis.

نویسندگان

  • Hong Yao
  • Xiaomei Huang
  • Peiying Shi
  • Zhen Lin
  • Meilan Zhu
  • Ailin Liu
  • Xinhua Lin
  • Yuhai Tang
چکیده

In this article, a DPPH·-luminol chemiluminescence (CL) system was reported and the CL mechanism was discussed according to the CL kinetic properties after sequence injecting DPPH· into the DPPH·-luminol reaction mixture. It was observed that scutellarin could inhibit the CL response of the DPPH·-luminol system. Based on this observation, a simple and rapid flow injection CL method was developed for the determination of scutellarin using the inhibition effect in alkaline medium. The optimized chemical conditions for the CL reaction were 5 × 10-6  mol/L DPPH· and 1.0 × 10-4  mol/L luminol in 0.01 mol/L NaOH. Under optimized conditions, the CL intensity was inversely proportional to the concentration of scutellarin over the ranges 5-2000 and 40-3200 ng/ml in pharmaceutical injection and rat plasma, respectively. The limits of detection (S/N = 3) were 5 and 40 ng/ml in preparations and rat plasma, respectively. Furthermore, the precision, recovery and stability of the validated method were acceptable for the determination of scutellarin in both pharmaceutical injections and rat plasma. The presented method was successfully applied in the determination of scutellarin in pharmaceutical injections and real rat plasma samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Terbium Sensitized Chemiluminescence Method for the Determination of Rabeprazole -Application to Pharmaceutical Analysis and Dissolution Studies

A simple and sensitive chemiluminescence-based method was established for the determination of rabeprazole.The proposed method was based on the enhancing effect of rabeprazole on Ce(IV)-Na2SO3 -Tb(III) chemiluminescence reaction. A possible mechanism was discussed for chemiluminescence system by studying UV-Vis, fluorescence and chemiluminescence spectra. The effects of va...

متن کامل

Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System

A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...

متن کامل

Luminol–K3Fe(CN)6 chemiluminescence system for the determination of glipizide

A rapid and sensitive flow-injection chemiluminescence (CL) method for the determination of glipizide was developed on the basis of finding that glipizide can enhance the CL intensity of the luminol-K3Fe(CN)6 system. In optimum condition, the increased CL intensity was directly proportional to the concentration of glipizide in the range from 4.0×10-8 g/mL to 1.0×10-6 g/mL and the detection limi...

متن کامل

Chemiluminescence determination of melamine with Luminol-K3Fe(CN)6 system

A sensitive chemiluminescence (CL) method was developed for determining melamine in urine and plasma samples based on the fact that melamine can remarkably enhance the chemiluminescence of Luminol-K3 Fe(CN)6 system in alkaline medium. The determination conditions were optimized. Under optimum conditions, the chemiluminescence intensity had a good linear relationship with melamine in the range o...

متن کامل

Direct Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid

Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Luminescence : the journal of biological and chemical luminescence

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2017