Quantitative comparison of the autofluorescence of bacteria and polystyrene microspheres under violet wavelength excitation for verification of fluorescence-based bioaerosol detector results.
نویسنده
چکیده
The autofluorescence intensity of bacteria and fungal spores was quantified by fluorescence microscopy in order to obtain the information for evaluating fluorescence-based bioaerosol detectors and was comparable to that of some types of polystyrene microspheres (PSMs). Although the intensity for microbes was distributed across a wide range over an order of magnitude in gray scale, it was in the intensity range of certain PSMs. Furthermore, some of those bacteria and PSMs were aerosolized in a test chamber and the fluorescence intensity was measured with a bioaerosol detector. Although there was a slight difference in the order of intensity from the results obtained by fluorescence microscopy, the fluorescence-based bioaerosol detector showed the intensity was in a comparable range.
منابع مشابه
Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix
A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...
متن کاملSynthesize and Optical properties of ZnO: Eu Microspheres Based Nano-sheets at Direct and Indirect Excitation
Europium (Eu) doped ZnO microsphere based nano-sheets were synthesized through hydrothermal method. Effects of different concentrations of Europium on structural and optical properties of ZnO nano-sheets were investigated in detail. Prepared un-doped and Eu-doped ZnO samples were characterized using X-Ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), scanning electron micro...
متن کاملIndividual bioaerosol particle discrimination by multi-photon excited fluorescence.
Femtosecond laser induced multi-photon excited fluorescence (MPEF) from individual airborne particles is tested for the first time for discriminating bioaerosols. The fluorescence spectra, analysed in 32 channels, exhibit a composite character originating from simultaneous two-photon and three-photon excitation at 790 nm. Simulants of bacteria aggregates (clusters of dyed polystyrene microspher...
متن کاملOptimized endoscopic autofluorescence spectroscopy for the identification of premalignant lesions in Barrett's oesophagus.
OBJECTIVE Fluorescence spectroscopy has the potential to detect early cellular changes in Barrett's oesophagus before these become visible. As the technique is based on varying concentrations of intrinsic fluorophores, each with its own optimal excitation wavelength, it is important to assess the optimal excitation wavelength(s) for identification of premalignant lesions in patients with Barret...
متن کاملA flash-lamp based device for fluorescence detection and identification of individual pollen grains.
We present a novel optical aerosol particle detector based on Xe flash lamp excitation and spectrally resolved fluorescence acquisition. We demonstrate its performances on three natural pollens acquiring in real-time scattering intensity at two wavelengths, sub-microsecond time-resolved scattering traces of the particles' passage in the focus, and UV-excited fluorescence spectra. We show that t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biocontrol science
دوره 18 4 شماره
صفحات -
تاریخ انتشار 2013