Modeling Airflow Using Subject-Specific 4DCT-Based Deformable Volumetric Lung Models

نویسندگان

  • Olusegun Ilegbusi
  • Zhiliang Li
  • Behnaz Seyfi
  • Yugang Min
  • Sanford L. Meeks
  • Patrick Kupelian
  • Anand P. Santhanam
چکیده

Lung radiotherapy is greatly benefitted when the tumor motion caused by breathing can be modeled. The aim of this paper is to present the importance of using anisotropic and subject-specific tissue elasticity for simulating the airflow inside the lungs. A computational-fluid-dynamics (CFD) based approach is presented to simulate airflow inside a subject-specific deformable lung for modeling lung tumor motion and the motion of the surrounding tissues during radiotherapy. A flow-structure interaction technique is employed that simultaneously models airflow and lung deformation. The lung is modeled as a poroelastic medium with subject-specific anisotropic poroelastic properties on a geometry, which was reconstructed from four-dimensional computed tomography (4DCT) scan datasets of humans with lung cancer. The results include the 3D anisotropic lung deformation for known airflow pattern inside the lungs. The effects of anisotropy are also presented on both the spatiotemporal volumetric lung displacement and the regional lung hysteresis.

منابع مشابه

A Biomechanical Model of Human Lung Deformation Utilizing Patient-Specific Elastic Property

A biomechanical model is developed and validated for breathing-induced deformation of human lung. Specifically, a subject-specific poro-elastic lung model is used to predict the displacement over the breathing cycle and compared with displacement derived from high resolution image registration. The lung geometry is derived from four-dimensional computed tomography (4DCT) scan dataset of two hum...

متن کامل

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

A complete 4DCT-ventilation functional avoidance virtual trial: Developing strategies for prospective clinical trials

INTRODUCTION 4DCT-ventilation is an exciting new imaging modality that uses 4DCT data to calculate lung-function maps. Because 4DCTs are acquired as standard of care for lung cancer patients undergoing radiotherapy, 4DCT-ventiltation provides functional information at no extra dosimetric or monetary cost to the patient. The development of clinical trials is underway to use 4DCT-ventilation imag...

متن کامل

Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations.

Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and are allowed to slide almost independently along the chest wall. This sliding mo...

متن کامل

Dynamic Multiscale Boundary Conditions for 4D CT of Healthy and Emphysematous Rats

Changes in the shape of the lung during breathing determine the movement of airways and alveoli, and thus impact airflow dynamics. Modeling airflow dynamics in health and disease is a key goal for predictive multiscale models of respiration. Past efforts to model changes in lung shape during breathing have measured shape at multiple breath-holds. However, breath-holds do not capture hysteretic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012