Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases.

نویسندگان

  • Hong Song
  • Bin He
  • Andrew Prideaux
  • Yong Du
  • Eric Frey
  • Wayne Kasecamp
  • Paul W Ladenson
  • Richard L Wahl
  • George Sgouros
چکیده

UNLABELLED The lungs are the most frequent sites of distant metastasis in differentiated thyroid carcinoma. Radioiodine treatment planning for these patients is usually performed following the Benua-Leeper method, which constrains the administered activity to 2.96 GBq (80 mCi) whole-body retention at 48 h after administration to prevent lung toxicity in the presence of iodine-avid lung metastases. This limit was derived from clinical experience, and a dosimetric analysis of lung and tumor absorbed dose would be useful to understand the implications of this limit on toxicity and tumor control. Because of highly nonuniform lung density and composition as well as the nonuniform activity distribution when the lungs contain tumor nodules, Monte Carlo dosimetry is required to estimate tumor and normal lung absorbed dose. Reassessment of this toxicity limit is also appropriate in light of the contemporary use of recombinant thyrotropin (thyroid-stimulating hormone) (rTSH) to prepare patients for radioiodine therapy. In this work we demonstrated the use of MCNP, a Monte Carlo electron and photon transport code, in a 3-dimensional (3D) imaging-based absorbed dose calculation for tumor and normal lungs. METHODS A pediatric thyroid cancer patient with diffuse lung metastases was administered 37 MBq of (131)I after preparation with rTSH. SPECT/CT scans were performed over the chest at 27, 74, and 147 h after tracer administration. The time-activity curve for (131)I in the lungs was derived from the whole-body planar imaging and compared with that obtained from the quantitative SPECT methods. Reconstructed and coregistered SPECT/CT images were converted into 3D density and activity probability maps suitable for MCNP4b input. Absorbed dose maps were calculated using electron and photon transport in MCNP4b. Administered activity was estimated on the basis of the maximum tolerated dose (MTD) of 27.25 Gy to the normal lungs. Computational efficiency of the MCNP4b code was studied with a simple segmentation approach. In addition, the Benua-Leeper method was used to estimate the recommended administered activity. The standard dosing plan was modified to account for the weight of this pediatric patient, where the 2.96-GBq (80 mCi) whole-body retention was scaled to 2.44 GBq (66 mCi) to give the same dose rate of 43.6 rad/h in the lungs at 48 h. RESULTS Using the MCNP4b code, both the spatial dose distribution and a dose-volume histogram were obtained for the lungs. An administered activity of 1.72 GBq (46.4 mCi) delivered the putative MTD of 27.25 Gy to the lungs with a tumor absorbed dose of 63.7 Gy. Directly applying the Benua-Leeper method, an administered activity of 3.89 GBq (105.0 mCi) was obtained, resulting in tumor and lung absorbed doses of 144.2 and 61.6 Gy, respectively, when the MCNP-based dosimetry was applied. The voxel-by-voxel calculation time of 4,642.3 h for photon transport was reduced to 16.8 h when the activity maps were segmented into 20 regions. CONCLUSION MCNP4b-based, patient-specific 3D dosimetry is feasible and important in the dosimetry of thyroid cancer patients with avid lung metastases that exhibit prolonged retention in the lungs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Papillary thyroid cancer with metastases to brain, lung and kidney: A case of dosimetry proven privilege of surgical resection of organ metastases

A 45-year-old woman presented with a headache and visual complaints. Brain MRI revealed a large mass in the right occipital cortex. The tumor was surgically removed and pathological examination showed papillary carcinoma originating from thyroid gland. She had a history of thyroid surgery 27 years ago indicating papillary thyroid cancer with central neck lymph node involvement followed by no ad...

متن کامل

Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

متن کامل

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...

متن کامل

A Case Report of Small Cell Lung Carcinoma in a Patient with Progressive Diffuse Sclerosis

 Connective tissue diseases, including scleroderma, may be associated with an increased risk of lung cancer. The most common type of lung cancer associated with systemic sclerosis is adenocarcinoma or bronchoalveolar carcinoma, and small cell carcinoma is rare. This reports presents a 54-year-old non-smoker woman with a history of scleroderma who was examined due to aggravation of shortness of ...

متن کامل

Lung Carcinoma Metastasis to the Distal Part of Index Finger: A Case Report

Although acrometastases are rare but clinically they are considered important. Their etiology is quite different from the metastases to other sites; bronchogenic carcinoma is by far the most frequent case. The prognosis is always similar to metastatic bronchial cancer with an average survival of three mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 2006