Programmable Muscle Stimulator for Activating Paralytic Patients

نویسندگان

  • Akin Cellatoglu
  • Balasubramanian Karuppanan
چکیده

Defective muscles and associated nerves affect the functioning of the parts of the human body leading to paralysis. In order to provide temporal recovery from paralysis the affected muscles can be identified and stimulated in a periodic sequence by driving required electrical current intensity into the muscle. The amplitude, frequency and pulse width of the muscle current are adjusted to see the response and their values are set up in accordance with the requirements demanded by the seriousness of the muscle defect. A programmable muscle stimulator operated by a microprocessor interfaced to PC is designed to meet this requirement and is reported.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ergonomic and Electronic Designing of Muscle Stimulator

The paper proposes a new ergonomic and electronic solution for the muscle stimulator. The device is programmable. It can be easily adjusted by the doctor, as well as by the patient. The design solution of this muscle stimulator has the improved interface. The device is safe to use and has determined ergonomic improvements. This muscle stimulator has small dimensions and light weight. The propos...

متن کامل

Application of a programmable dual-channel adaptive electrical stimulation system for the control and analysis of gait.

A dual-channel electrical stimulation system with a stimulator and a programmer/stride analyzer was designed for clinical rehabilitation of gait and for subsequent daily use as an orthotic aid. The stimulator, with controls to adjust amplitude only (50 mA), adapts chosen stimulation sequences to the walking rate of a patient. Pulse duration (50-500 microseconds), frequency (5-120 Hz), shape (sy...

متن کامل

The Implementation of DSP-Based Controller for a Multichannel Programmable Electrical Stimulation System and Its User-Friendly Man-Machine Interface Design

Electrical stimulators have been applied in many fields for many decades, especially in restoring the muscle activities of paralyzed patients who suffer from spinal cord injuries or related neural impairments. In this paper, a DSP-based multichannel programmable electrical stimulation system is proposed. The “element-envelope” method is also used for flexible and arbitrary waveform generation a...

متن کامل

Muscle Union Procedure in Patients with Paralytic Strabismus

To present the surgical outcomes of a muscle union procedure in patients with paralytic strabismus, this retrospective study included 27 patients with paralytic strabismus who underwent a muscle union procedure. In this procedure, the two vertical rectus muscles are united with the paralytic horizontal muscle without splitting the muscles. Postoperative ocular deviations, complications, surgica...

متن کامل

EFFECTS OF CHRONIC ADMINISTRATION OF TWO NEWLY SYNTHESIZED NONDEPOLARIZING NEUROMUSCULAR BLOCKING AGENTS

The potential changes In neuromuscular blockade after chronic (>24 h) administration of sub-paralytic doses of two newly introduced aminosteroidal muscle relaxants were investigated. Org-9426 (rocuronium) and Org-9487 were studied in the in vivo guinea pig gastrocnemius muscle-sciatic nerve preparation. The problems seen after prolonged administration of muscle relaxants are thought to ari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -