Effects of Poultry Building Design on Indoor Air Quality in Humid Climates

نویسنده

  • H. E. Polat
چکیده

In this study, six poultry buildings, consisting of four layer hen houses and two broiler houses located in Manisa Province in Turkey, were examined to find out the effects of planning systems on indoor environmental conditions where the age of litter for broiler ranged from 4-18 weeks and the age of commercial layer hens ranged from 22-43 weeks. Air quality parameters, as concentrations of ammonia, carbon dioxide and methane were measured by using multi-gas monitor. Other parameters, as temperature/relative humidity and particulate matter were measured by using respectively, psychrometric sensors and multi-function meter. These measurements were obtained as four replicates for each building in winter, early spring, and summer. The measured data were evaluated via repeated measures analysis of variance (rANOVA). According to the research results, measured indoor temperature values tend to rise in Californian cage type buildings in all seasons (max. 27.65 °C in winter and max. 41.85 °C in summer). The highest relative humidity values were measured in deep litter type buildings (max. 76.27 % in winter and max. 80.44 % in summer). Particulate matter levels had high values in Californian cage type buildings in summer (Avg. 1.09 mg/m3) and in deep litter type buildings in winter (Avg. 3.16 mg/m3). Concentrations of NH3 and CH4 had high levels in Californian cage type (34.68 ppm NH3 and 15.14 ppm CH4 max. values) and deep litter type (49.54 ppm NH3 and 19.32 ppm CH4 max. values) buildings in winter. NH3 and CH4 have a tendency to rise in all types of buildings in summer. CO2 had the highest levels in Californian cage type (max. 1805.57 ppm) and deep litter type (max. 8906.33 ppm) buildings in all seasons. Concentrations of CO2 had lower levels in summer than in winter in all types of poultry buildings. Statistical analysis showed that the design of poultry buildings determined indoor environmental conditions. Also, hot and humid local climate has the effects on indoor air quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study on Numerical Simulation Applied to Moisture Buffering Design Method – The Case Study of Pine Wood in a Single Zone Residential Unit in Taiwan

A good green building design project, designers should consider not only energy consumption, but also healthy and comfortable needs of inhabitants. In recent years, the Taiwan government paid attentions on both carbon reduction and indoor air quality issues, which be presented in the legislation of Building Codes and other regulations. Taiwan located in hot and humid climates, dampness in build...

متن کامل

Humidity Control in School Facilities

Consulting engineers who design school facilities are challenged with controlling space humidity while also providing continuous ventilation as required by ASHRAE Standard 62-1999, now part of most major building codes. What would appear to be a simple design process is complicated by various logistical and operational factors. Schools, by nature, have a high occupant density which results in l...

متن کامل

Evaluation of air quality in intensive care units and its relationship with sick building syndrome in nurses

Introduction: Indoor air quality can lead to health problems such as Sick Building Syndrome among nurses who spend many hours in intensive care units.The aim of this study was to determine the relationship between Sick Building Syndrome in nurses and indoor air quality of intensive care units in educational hospitals in Rasht. Materials and Methods: This cross-sectional analytical study was pe...

متن کامل

Investigation on mycoflora of poultry breeding houses’ air and studying the efficacy of spraying and fumigation on inactivating the airspora

Background: A common concern of the poultry industry is the presence of fungal pathogens in the birds’ environment, which may constitute a considerable health hazard to the birds, farmers, and those living in proximity of the farm. OBJECTIVES: The aims of this study were to assess the mycoflora in the indoor and outdoor environments of poultry breeding houses and studying the efficacy of disinf...

متن کامل

An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls' High Schools in Arak, Iran)

As s‌tudents spend one-third of their time at school, their health, comfort, and productivity are mos‌tly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and s‌tudents aren't allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015