Lesion detectability in diagnostic ultrasound with short-lag spatial coherence imaging.

نویسندگان

  • Jeremy J Dahl
  • Dongwoon Hyun
  • Muyinatu Lediju
  • Gregg E Trahey
چکیده

We demonstrate a novel imaging technique, named short-lag spatial coherence (SLSC) imaging, which uses short distance (or lag) values of the coherence function of backscattered ultrasound to create images. Simulations using Field II are used to demonstrate the detection of lesions of varying sizes and contrasts with and without acoustical clutter in the backscattered data. B-mode and SLSC imaging are shown to be nearly equivalent in lesion detection, based on the contrast-to-noise ratio (CNR) of the lesion, in noise-free conditions. The CNR of the SLSC image, however, can be adjusted to achieve an optimal value at the expense of image smoothness and resolution. In the presence of acoustic clutter, SLSC imaging yields significantly higher CNR than B-mode imaging and maintains higher image quality than B-mode with increasing noise. Compression of SLSC images is shown to be required under high-noise conditions but is unnecessary under no- and low-noise conditions. SLSC imaging is applied to in vivo imaging of the carotid sheath and demonstrates significant gains in CNR as well as visualization of arterioles in the carotid sheath. SLSC imaging has a potential application to clutter rejection in ultrasonic imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results.

Short-lag spatial coherence (SLSC) imaging is a novel beamforming technique that reduces acoustic clutter in ultrasound images. A clinical study was conducted to investigate clutter reduction and endocardial border detection in cardiac SLSC images. Individual channel echo data were acquired from the left ventricle of 14 volunteers, after informed consent and institutional review board approval....

متن کامل

Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds.

Prostate brachytherapy, administered by implanting tiny radioactive seeds to treat prostate cancer, currently relies on transrectal ultrasound imaging for intraoperative visualization of the metallic seeds. Photoacoustic (PA) imaging has been suggested as a feasible alternative to ultrasound imaging due to its superior sensitivity to metal surrounded by tissue. However, PA images suffer from po...

متن کامل

Importance of defect detectability in Positron Emission Tomography imaging of abdominal lesions

Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...

متن کامل

Development and validation of a short-lag spatial coherence theory for photoacoustic imaging

We previously derived a theoretical expression for spatial coherence in photoacoustic data and utilized it to study properties of the short-lag spatial coherence (SLSC) beamformer applied to photoacoustic imaging. In this paper, an updated version of our theoretical equation is evaluated to generate SLSC images of a point target, a 1.2 mm diameter target, and corresponding lateral profiles thro...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasonic imaging

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 2011