Correcting Illumina data

نویسندگان

  • Michael Molnar
  • Lucian Ilie
چکیده

Next-generation sequencing technologies revolutionized the ways in which genetic information is obtained and have opened the door for many essential applications in biomedical sciences. Hundreds of gigabytes of data are being produced, and all applications are affected by the errors in the data. Many programs have been designed to correct these errors, most of them targeting the data produced by the dominant technology of Illumina. We present a thorough comparison of these programs. Both HiSeq and MiSeq types of Illumina data are analyzed, and correcting performance is evaluated as the gain in depth and breadth of coverage, as given by correct reads and k-mers. Time and memory requirements, scalability and parallelism are considered as well. Practical guidelines are provided for the effective use of these tools. We also evaluate the efficiency of the current state-of-the-art programs for correcting Illumina data and provide research directions for further improvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correcting Illumina sequencing errors for human data

Summary: We present a new tool to correct sequencing errors in Illumina data produced from high-coverage whole-genome shotgun resequencing. It uses a non-greedy algorithm and shows comparable performance and higher accuracy in an evaluation on real human data. This evaluation has the most complete collection of highperformance error correctors so far. Availability and implementation: https://gi...

متن کامل

An adaptive decorrelation method removes Illumina DNA base-calling errors caused by crosstalk between adjacent clusters

Base-calling accuracy is crucial for high-throughput DNA sequencing and downstream analysis such as read mapping and genome assembly. Accordingly, we made an endeavor to reduce DNA sequencing errors of Illumina systems by correcting three kinds of crosstalk in the cluster intensity data. We discovered that signal crosstalk between adjacent clusters accounts for a large portion of sequencing err...

متن کامل

QuorUM: An Error Corrector for Illumina Reads

MOTIVATION Illumina Sequencing data can provide high coverage of a genome by relatively short (most often 100 bp to 150 bp) reads at a low cost. Even with low (advertised 1%) error rate, 100 × coverage Illumina data on average has an error in some read at every base in the genome. These errors make handling the data more complicated because they result in a large number of low-count erroneous k...

متن کامل

A Comparison of Next Generation Sequencing Technologies for Transcriptome Assembly and Utility for RNA-Seq in a Non-Model Bird

De novo assembled transcriptomes, in combination with RNA-Seq, are powerful tools to explore gene sequence and expression level in organisms without reference genomes. Investigators must first choose which high throughput sequencing platforms will provide data most suitable for their experimental goals. In this study, we explore the utility of 454 and Illumina sequences for de novo transcriptom...

متن کامل

BFC: correcting Illumina sequencing errors

UNLABELLED BFC is a free, fast and easy-to-use sequencing error corrector designed for Illumina short reads. It uses a non-greedy algorithm but still maintains a speed comparable to implementations based on greedy methods. In evaluations on real data, BFC appears to correct more errors with fewer overcorrections in comparison to existing tools. It particularly does well in suppressing systemati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Briefings in bioinformatics

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2015