Clinical Roles of Lung Volumes Detected by Body Plethysmography and Helium Dilution in Asthmatic Patients: A Correlation and Diagnosis Analysis
نویسندگان
چکیده
Roles of lung volumes in asthma remain controversial. We aimed to evaluate the efficacy of lung volumes in differentiating asthma severity levels. Consecutive outpatients with chronic persistent asthma were enrolled, and body plethysmography (BP) and helium dilution (HD) were performed simultaneously to extract RV%pred, TLC%pred, and RV/TLC. Significant negative correlations were found between FEV1%pred and RV%pred (r = -0.557, P < 0.001), TLC%pred (r = -0.387, P < 0.001), and RV/TLC (r = -0.485, P < 0.001) measured by BP, as well as difference in volumes between these two techniques (ΔRV%pred, ΔTLC%pred and ΔRV/TLC). In mild and moderate asthma, AUC of RV%pred detected by BP and ΔTLC%pred was 0.723 (95%CI 0.571-0.874, P = 0.005) and 0.739 (95%CI 0.607-0.872, P = 0.002) with sensitivity and specificity being 79.41% and 88.24%, and 65.22% and 56.52% at cut-off of 145.40% and 14.23%, respectively. In moderate and severe asthma, AUC of RV%pred detected by BP and ΔTLC%pred was 0.782 (95%CI 0.671-0.893, P < 0.001) and 0.788 (95%CI 0.681-0.894, P < 0.002) with sensitivity and specificity being 77.78% and 97.22%, and 73.53% and 52.94% at cut-off of 179.85% and 20.22%, respectively. In conclusion, lung volumes are reliable complement of FEV1 in identifying asthma severity levels.
منابع مشابه
The measurement of lung volumes using body plethysmography and helium dilution methods in COPD patients: a correlation and diagnosis analysis
Chronic obstructive pulmonary disease (COPD) is a chronic airway disease characterized by persistent airflow limitation. Moreover, lung hyperinflation evaluated by lung volumes is also the key pathophysiologic process during COPD progression. Nevertheless, there is still no preferred method to evaluate lung volumes. For this study, we recruited 170 patients with stable COPD to assess lung volum...
متن کاملCritical evaluation of computerised x ray planimetry for the measurement of lung volumes.
BACKGROUND Computerised x-ray planimetry has been advocated as an alternative to body plethysmography and helium dilution for measuring static lung volumes. The accuracy and reproducibility of this method has been assessed in comparison with these standard methods. METHODS Plethysmographic and planimetric measurements of total lung capacity (TLC) and functional residual capacity (FRC) were ma...
متن کاملComparison of two new methods for the measurement of lung volumes with two standard methods.
BACKGROUND The two most commonly used methods for the measurement of lung volumes are helium dilution and body plethysmography. Two methods have been developed which are both easier and less time consuming to perform. Mathematical modelling uses complex calculations from the flow-volume loop to derive total lung capacity (TLC), and the nitrogen balance technique uses nitrogen from the atmospher...
متن کاملComparison of helium dilution and plethysmographic lung volumes in pregnant women.
The multibreath helium equilibration method is the technique recommended for routine measurement of static lung volumes in normal subjects. However, pregnancy could be an exception to this general rule, due to airway closure during the second half of gestation. The aim of this study was to compare the measurements of lung volumes by plethysmography and helium dilution during pregnancy. Twenty t...
متن کاملCan the single-breath helium dilution method predict lung volumes as measured by whole-body plethysmography?*
OBJECTIVE To compare TLC and RV values obtained by the single-breath helium dilution (SBHD) method with those obtained by whole-body plethysmography (WBP) in patients with normal lung function, patients with obstructive lung disease (OLD), and patients with restrictive lung disease (RLD), varying in severity, and to devise equations to estimate the SBHD results. METHODS This was a retrospecti...
متن کامل