Comparison of three methods of measuring corneal thickness and anterior chamber depth.
نویسندگان
چکیده
PURPOSE To compare three different methods of measuring corneal thickness (CT) and anterior chamber depth (ACD). DESIGN Prospective clinical trial (Medical University of Vienna, Austria). METHODS Central CT (CCT), CT at four peripheral points, and central ACD were measured in 88 eyes of 44 healthy subjects with the Pentacam (rotating Scheimpflug camera; Oculus, Wetzlar, Germany), Orbscan I (scanning-slit topography system; Orbtek Inc, Salt Lake City, Utah, USA), and AC-Master (partial coherence interferometry; Zeiss Meditec, Jena, Germany), and the results were compared. RESULTS The upper (lower) limits of agreement for CCT measurements were 7.9 (-22.2) microm between AC-Master and Pentacam, 17.6 (-32.5) microm between AC-Master and Orbscan, and 25.2 (-25.9) microm between Pentacam and Orbscan. Correlation was high between all three methods (r = 0.94 to 0.97). The upper and lower limits of agreement for ACD were 0.174 (-0.251) mm between AC-Master and Pentacam, 0.406 (-0.004) mm between AC-Master and Orbscan, and 0.384 (0.095) mm between Pentacam and Orbscan. Correlation was high between the three methods (r = 0.96 between Orbscan and Pentacam; others 0.92). Correlation was lower for the CT measurements at the four peripheral points. CONCLUSIONS The CCT and ACD values obtained by Pentacam, Orbscan, and AC-Master measurements correlated well and showed few outliers. The two new systems (Pentacam, AC-Master) provide a reliable, easy-to-use, noncontact method of measuring CCT and ACD. Larger differences occurred only when measuring peripheral CT values, especially between AC-Master and the other two methods.
منابع مشابه
The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure
Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...
متن کاملComparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth
Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan) and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA) for measuring central corneal thickness (CCT), anterior chamber depth (ACD), and aqueous depth (AD). Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this pros...
متن کاملOcular biometry and central corneal thickness in children: a hospital-based study.
PURPOSE To investigate the distribution of axial length, anterior chamber depth, lens thickness, vitreous chamber depth, and central corneal thickness in children at different age groups. METHODS We studied 364 eyes in 182 children with ages between 1 and 12 years. Axial length, anterior chamber depth, lens thickness, and vitreous chamber depth were measured by ultrasound biometry. Central co...
متن کاملCentral corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and Pentacam.
PURPOSE To evaluate the agreement among three different optical methods in measuring anterior chamber depth (ACD), central corneal thickness (CCT), and pupil diameter. METHODS One hundred eyes of 50 healthy patients (25 men, 25 women) were enrolled in the study. Mean patient age was 25 years (range: 21 to 32 years). Exclusion criteria were history of any intraocular or corneal surgery, contac...
متن کاملSubmicrometer precision biometry of the anterior segment of the human eye.
PURPOSE To demonstrate the feasibility of measuring the anterior structures of the human eye by partial coherence interferometry and to determine its precision for eyes under normal and cycloplegic conditions. METHODS The dual-beam version of partial coherence interferometry, a recently developed noninvasive optical ranging technique, enables high resolution measurements of several intraocula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of ophthalmology
دوره 141 1 شماره
صفحات -
تاریخ انتشار 2006