The Volume Embolization Ratio of Intraaneurysmal Embolization Using Guglielmi Detachable Coils.
نویسندگان
چکیده
AIM To analyse the relationship between the Volume Embolization Ratio (VER), aneurysmal morphological characteristics, and intracranial aneurysm embolization results. MATERIAL AND METHODS Using the clinical and radiological data of 57 cerebral aneurysms treated with detachable coils, VERs were calculated. The relationship between the VER and aneurysm embolization was analysed. RESULTS We observed that the mean VERs of the small, medium, large, and giant aneurysms were 40.8±26.5%, 18.6±16.1%, 2.3±2.1% and 0.4±0.1%, respectively and the differences were statistically significant (F=7.091, P=0.000). The mean VERs of the wide- and small-necked aneurysms were 27.5±23.1% and 29.4±26.6%, respectively. There was no significant difference between these values. The mean VERs of aneurysms causing complete occlusion, neck residual and partial embolization were 41.8±29.3%, 31.4±21.2%, 12.3±15.1%, respectively, and the differences were statistically significant (F=7.97, p=0.001). CONCLUSION The VER is an objective index with which to evaluate aneurysm embolization and is a significant predictor of the efficacy of intracranial aneurysm embolization.
منابع مشابه
New predictor for intraaneurysmal embolization using Guglielmi detachable coils.
Aneurysm volume/virtual column volume (AV/CV) ratio, calculated from measurements derived from reconstructed images based on rotational three-dimensional digital subtraction angiography (3D-DSA), was investigated as a predictor of the success of intraaneurysmal embolization in 20 unruptured wide-necked internal carotid artery aneurysms treated by Guglielmi detachable coils. AV and neck area wer...
متن کاملThrombosis in giant basilar tip aneurysms during coil embolization.
Two patients with giant basilar tip aneurysms underwent coil embolization, one with both platinum fiber and platinum Guglielmi detachable coils and the other with Guglielmi detachable coils only. In both cases, spontaneous intraaneurysmal thrombosis occurred outside the coil mass, presumably a result of disruption of the intraaneurysmal flow pattern.
متن کاملTransarterial embolization of a direct carotid cavernous fistula with Guglielmi detachable coils.
Four patients underwent transarterial embolization of a carotid-cavernous fistula with Guglielmi detachable coils; in three cases as the initial form of treatment and in one case after treatment via transarterial balloon embolization failed. The fistulas were 2 to 3 mm in diameter on pretreatment angiograms. Complete obliteration was achieved in two patients; in the other two, minimal residual ...
متن کاملEndovascular embolization of unruptured vertebral dissection using Guglielmi electrolytically detachable coils: case report.
We present a patient with unruptured vertebral dissection whose angiograph showed further enlargement of the aneurysm, after a transient reduction in the size of the fusiform dilatation. Tolerance of parent artery occlusion was first confirmed by a balloon occlusion test. Both proximal and distal portions of the vertebral artery, including the dissected site, were occluded using Guglielmi elect...
متن کاملEndovascular intervention of intradural hemorrhage from ruptured spontaneous vertebral artery dissection.
OBJECTIVE To study the therapeutic effect of endovascular treatment for intradural hemorrhage from ruptured spontaneous vertebral artery dissections (SVAD) using Guglielmi detachable coils and mechanical coils. METHODS The retrospective study was carried out in the Department of Interventional Radiology, Rizhao People`s Hospital, Rizhao, China from January 2008 to December 2011. Twelve patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Turkish neurosurgery
دوره 25 6 شماره
صفحات -
تاریخ انتشار 2015