Reduction of Dose to the Contralateral Breast by Superflab Use in Radiation Therapy for Mammary Carcinomas

نویسندگان

  • Akanksha Solanki
  • Athiyaman M
  • Hemalatha A
  • H S Kumar
چکیده

Background: Radiation therapy is an integral part of multimodality treatment for locally advanced carcinoma of breast. Radiation doses to nearby critical normal structures like heart, lungs, and contralateral breast (CLB increases risk of second malignancies. In this study, we measured doses to the CLB and studied effects of a 1 cm thickness superflap. Materials and Methods: Fifty post-mastectomy carcinoma breast patients were included in the study.Radiation therapy of 50 Gy was planned in 25 fractions, 5 days a week, using the Eclipse Treatment Planning System version 8.9.15, with a pencil beam convolution algorithm and 6 MV photon beam. Plans were transferred to a linear accelerator (Varian 2300 CD) for execution of treatment. Twenty-four CaSO4 thermoluminescent dosimeter discs (TLDs) were used for dose measurement over the CLB. The dose was measured for each patient without a superflab for ten fractions and with for another ten fractions for subsequent comparison. Results: Mean doses/fractions received by the CLB with and without a superflab? were 3.78 ± 1.29 cGy and 7.82 ± 2.62 cGy, respectively, with total dosees of 94.69 ± 32.43 cGy (1.89% of prescribed dose) and 191.14 ± 65.62 cGy (3.82% of prescribed dose). The average reduction in mean dose with a 1 cm thick superflab was 46.57 ± 17.18%, in the range of 20 to 80% and statistically significant (p < 0.001). Conclusion: Superflab? is an effective method for dose reduction to CLB. It is an easy, convenient and low time consuming method. Elucidation of any role in reduction of 2nd malignancies in CLB now needs large studies with long follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy

The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radioth...

متن کامل

Measuring the photon and thermal neutron dose values of contralateral breast surface undergone breast cancer radiation therapy

This research aimed to measure the received photon and thermal neutron doses to contralateral breast (CB) surface in breast cancer radiation therapy for different field sizes in presence of dynamic and physical wedges. The photon and thermal neutron doses were measured by thermo uminescent dosimeter (TLDs) chips for 11 × 13, 11 × 17 and 11 × 21 cm2 field sizes in presence of physical and dynamic ...

متن کامل

Designing a shield to reduce radiation dose during mammography: Dosimetric evaluation

Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance.  Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...

متن کامل

Effect of uniform magnetic field on dose distribution in the breast radiotherapy

Background: To reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. Materials and Methods: Monte Carlo simulations were performed with GEANT4, irradiating humanoid phantoms in a magnetic field. To reconstruct phantoms, computed tomography (CT) data slices of four patients were used for the Monte Car...

متن کامل

A comparison of contralateral breast dose due to breast cancer radiotherapy using two different treatment machines in a radiotherapy center

Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017