Radiolucent lines and component stability in knee arthroplasty. Standard versus fluoroscopically-assisted radiographs.

نویسندگان

  • P Vyskocil
  • C Gerber
  • P Bamert
چکیده

The radiolucent lines and the stability of the components of 66 knee arthroplasties were assessed by six orthopaedic surgeons on conventional anteroposterior and lateral radiographs and on fluoroscopic views which had been taken on the same day. The examiners were blinded as to the patients and clinical results. The interpretation of the radiographs was repeated after five months. On fluoroscopically-assisted radiographs four of the six examiners identified significantly more radiolucent lines for the femoral component (p < 0.05) and one significantly more for the tibial implant. Five examiners rated more femoral components as radiologically loose on fluoroscopically-assisted radiographs (p = 0.0008 to 0.0154), but none did so for the tibial components. The mean intra- and interobserver kappa values were higher for fluoroscopically-assisted radiographs for both components. We have shown that fluoroscopically-assisted radiographs allow more reproducible, and therefore reliable, detection of radiolucent lines in total knee arthroplasty. Assessment of the stability of the components is significantly influenced by the radiological technique used. Conventional radiographs are not adequate for evaluation of the stability of total knee arthroplasty and should be replaced by fluoroscopically-assisted films.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of radiolucent lines around the Oxford unicompartmental knee replacement: sensitivity and specificity for loosening.

The Oxford unicompartmental knee replacement gives good results in patients with symptomatic osteoarthritis of the medial compartment. Previous studies have suggested that the presence of radiolucent lines (RLLs) does not reflect a poor outcome in such patients. However, the reliability and validity of this assessment have not been determined. Our aim was to assess the intra- and interobserver ...

متن کامل

The early radiological follow-up of a medial rotational design of total knee arthroplasty.

The objective of this study was to investigate the hypothesis that the increased constraint of a medial rotational knee promotes earlier loosening of the prosthesis. All patients with a Freeman-Samuelson 1000 knee arthroplasty (medial pivot design), (group 1), or a Freeman-Samuelson Modular knee arthroplasty, (group 2), with a minimum follow-up of 2 years (mean follow-up 4 years) were identifie...

متن کامل

Comparison of cementless and hybrid cemented total knee arthroplasty.

Cementless total knee arthroplasty (TKA) implants were designed to provide long-term fixation without the risk of cement-associated complications. The purpose of this study was to evaluate the outcome of titanium-coated cementless implants compared with hybrid TKA implants with a cemented tibial and a cementless femoral component. The authors performed a case-control, single-center study of 120...

متن کامل

Humeral-sided Radiographic Changes Following Reverse Total Shoulder Arthroplasty

Background: We sought to characterize humeral-sided radiographic changes at a minimum of 2 years after reverseshoulder arthroplasty (RSA) to determine their association with specific implantation techniques.Methods: The immediate and most recent postoperative anteroposterior radiographs of 120 shoulders with primary RSAand a minimum of 2-years of radiographic follow-up were an...

متن کامل

Survival and radiographic analysis of a glenoid component with a cementless fluted central peg.

BACKGROUND Aseptic loosening of glenoid components is a common problem associated with total shoulder arthroplasty and one cause for failure. A new cementless fluted glenoid component was developed and has shown excellent bony ingrowth in a canine model. HYPOTHESIS Clinical utilization of this cementless fluted pegged glenoid component in total shoulder arthroplasty would lower rates of radio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 1999