Revision of tibial TKA components: bone loss is independent of cementing type and technique: an in vitro cadaver study

نویسندگان

  • Turgay Efe
  • Jens Figiel
  • David Sibbert
  • Susanne Fuchs-Winkelmann
  • Carsten O Tibesku
  • Nina Timmesfeld
  • Jürgen RJR Paletta
  • Adrian Skwara
چکیده

BACKGROUND Different bone cements and various cementation techniques can lead to different bone loss in revision surgery. We investigated the degree of tibial bone loss depending on different cements and techniques. METHODS 30 tibia specimens were matched into three groups (10 each). In all cases Genesis II tibia component were implanted. In two groups, the tibia base plate alone was cemented with Palacos® R+G and Refobacin® Bone Cement R. In the third group, both tibial base plate and tibial stem were cemented with Palacos® R+G. Afterwards, the specimens were axial loaded with 2000 N for 10,000 cycles. Tibial components were explanted and the required time to explantation was recorded. Bone loss after explantation was measured by CT. RESULTS On CT, there was no significant difference in bone loss between cementing techniques (p = 0.077; 95% CI -1.14 - 21.03) or the cements themselves (p = 0.345; 95% CI -6.05 - 16.70). The required time to explantation was 170.6 ± 54.89, 228.7 ± 84.5, and 145.7 ± 73.0 seconds in the first, second, and third groups, respectively. CONCLUSIONS Cement technique and type do not influence tibial bone loss in simulated revision surgery of the tibial component in knee arthroplasty.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal Analysis of the Tibial Cement Interface with Modern Cementing Technique

BACKGROUND The major cause of cemented Total Knee Arthroplasty (TKA) failure is aseptic loosening of the tibial component necessitating revision surgery. Recently, multiple techniques have been described to maximize cement penetration depth and density in the proximal tibia during TKA to potentially avoid early loosening. While cement polymerisation is an exothermic reaction, minimal investigat...

متن کامل

Effect of Tibial Tray Malalignment on Micromotion and Subsidence: A Preliminary Report

Malalignment of the tibial tray in total knee arthroplasty has been linked to several complications including tibial tray subsidence, leading to revision surgery. However, quantitative biomechanical evidence to directly support the mechanism of failure is not available. We developed a model to study tibial tray micromotion and subsidence in vitro under multiaxial physiological loading condition...

متن کامل

Full versus surface tibial baseplate cementation in total knee arthroplasty.

The use of a keel in the tibial component during modern primary total knee arthroplasty (TKA) has become common, and its cementation may affect the future performance of the prosthesis. Although proponents of cementing the entire tibial component argue that this technique provides better initial fixation and may prevent aseptic loosening, reasons exist to apply cement only to the tibial basepla...

متن کامل

Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model

BACKGROUND In total knee arthroplasty (TKA), cement penetration between 3 and 5 mm beneath the tibial tray is required to prevent loosening of the tibia component. The objective of this study was to develop and validate a reliable in vivo measuring technique using CT imaging to assess cement distribution and penetration depth in the total area underneath a tibia prosthesis. METHODS We defined...

متن کامل

The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty

Little data exists regarding outcomes following TKA performed with surface-cementation for the fixation of modular tibial baseplates with press-fit keels. Thus, we retrospectively reviewed the clinical and radiographic outcomes of 439 consecutive primary TKAs performed with surface cemented tibial components. There were 290 female patients and 149 male patients with average age of 62 years (ran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011