Psychophysical assessment of stimulation sites in auditory prosthesis electrode arrays.

نویسندگان

  • Bryan E Pfingst
  • Rose A Burkholder-Juhasz
  • Teresa A Zwolan
  • Li Xu
چکیده

Auditory prostheses use implanted electrode arrays that permit stimulation at many sites along the tonotopic axis of auditory neurons. Psychophysical studies demonstrate that measures of implant function, such as detection and discrimination thresholds, vary considerably across these sites, that the across-site patterns of these measures differ across subjects, and that the likely mechanisms underlying this variability differ across measures. Psychophysical and speech recognition studies suggest that not all stimulation sites contribute equally to perception with the prosthesis and that some sites might have negative effects on perception. Studies that reduce the number of active stimulation sites indicate that most cochlear implant users can effectively utilize a maximum of only about seven sites in their processors. These findings support a strategy for improving implant performance by selecting only the best stimulation sites for the processor map. Another approach is to revise stimulation parameters for ineffective sites in an effort to improve acuity at those sites. In this paper, we discuss data supporting these approaches and some potential pitfalls.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Electrode Array for Retinal Stimulation

In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...

متن کامل

Inner ear implants for experimental electrical stimulation of auditory nerve arrays.

Electrode arrays chronically implanted in the inner ear are gaining increased use for experimental studies of the auditory nervous system, as well as for studies related to development of improved auditory prostheses. Commercially available electrode arrays are designed for human use and thus may be unsuitable for experimental studies, particularly in small animals. This paper describes a simpl...

متن کامل

Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article

The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...

متن کامل

Predicting visual sensitivity in retinal prosthesis patients.

PURPOSE With the long-term goal of restoring functional vision in patients with retinal degenerative diseases, the eyes of blind human subjects were implanted chronically with epiretinal prostheses consisting of two-dimensional electrode arrays that directly stimulated cells of the neural retina. METHODS Psychophysical techniques were used to measure the brightness of electrically generated p...

متن کامل

Histological and physiological effects of the central auditory prosthesis: surface versus penetrating electrodes.

To rehabilitate profoundly deaf patients who are not suitable for cochlear implants, central auditory prostheses have been implanted. To compare two possible electrode configurations - penetrating and surface ones - electrical stimulation of the cochlear nucleus with both types of arrays was tested on guinea pigs and cats. Electrophysiological, autoradiographic and histological measures were us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hearing research

دوره 242 1-2  شماره 

صفحات  -

تاریخ انتشار 2008