Load flow control and optimization using phase shifting equipment in combination with Banverkets rotating converters

نویسنده

  • Klas Karlsson
چکیده

The purpose of the thesis was to further investigate the possibility to complement the rotary converters with a phase shifting device as a continuation of the work done in the master thesis; Load flow control and optimization of Banverkets 132 kV 16 2/3 Hz high voltage grid. With this modification, rotating converters can be used almost as flexible as static converters. The earlier thesis has come to the conclusion that the best way of compensating the phase displacement is with a series inductance. In this thesis the possibility to use capacitors instead of or in combination with inductors was investigated. To investigate this three different models were built: One for the railway between Häggvik (Stockholm) and Boden; the same model that was used in the earlier thesis; it was used to confirm the results, one for the railway between Boden and Haparanda and one model that was the same as for the Haparanda track but half the distance. The models were built in the simulation program SIMPOW. The results from the simulations performed for the railway between Boden and Häggvik confirmed the results from the earlier thesis, with a series inductance as phase shifter. For the railway between Boden and Haparanda one phase shifting device consisting of reactors and one consisting of a combination of reactors and capacitors were dimensioned. The railway with half the length compared to the Haparanda track was used to see if the length of the track in a low impedance transmission system has a large influence of the size of the reactances needed. From the simulation the conclusion can be drawn that the track length does not have a large influence when suitable reactances are chosen. It is the size of the load and the phase angle that matter when choosing reactances. For the Haparanda track it is possible to save power. With a phase shifter that consists of reactors that is placed in the converter station in Kalix, power savings of 340 MWh/year were achieved. With a combination of reactors and capacitors with the capacitors in the converter station in Boden and reactors in the converter station in Kalix power savings of 750 MWh/year were achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Operation of Microgrids Under Demand Side Management

One of the major problem in the optimal operation of the power system is optimal operation of microgrid with regard to the Demand-side-management. From one side, demand-side-management programs  reduce the operating costs of the power system and on the other hand, the implementation of these programs requires a financial incentive policies. In this paper, optimal operation of microgrid with dem...

متن کامل

Three-Phase to Single-Phase Matrix Converters: New Topology Based on New Control Method

In this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. In addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. In the proposed control metho...

متن کامل

A Novel Transformer-Based Single-to-Three Phase Conversion Technique Using Rotating Magnetic Field Theory

This paper presents a new single to three phase converter using rotating magnetic field transformer. Conventional transformers have been used in many converters aiming at supplementary improvements and they usually have no critical effect on the conversion technique. In this paper, the conversion technique is based on a special rotating magnetic field transformer in which there are two windings...

متن کامل

Parallel Operation of Hybrid Loaded Resonant Converter Using Phase-Shift Control

This paper presents a phase shifting method to adjust the combined output voltage of two Hybrid Loaded Resonant Converters connected in parallel. The method implements a fixed switching frequency and hence it is particularly useful in applications such as medical instrumentation where audible noise is not desirable. The design and analysis of parallel Hybrid Resonant Converters operating in dis...

متن کامل

Control of a Fluidized Bed Polyethylene Reactor

In present paper, dynamic behavior and control of a fluidized bed reactor for polyethylene production has been considered. A double active sites model for Ziegler-Natta catalysts is used for simulation of polymerization reaction. Hydrodynamic behavior of the bed is modeled using a two phase model including bubble and emulsion phases in which bubble phase has plug flow pattern with different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006