Development of individual insulin infusion profiles for open loop infusion systems.

نویسندگان

  • T Strack
  • U Krause
  • G Schulz
  • J Beyer
  • F Beutelspacher
  • J Nagel
چکیده

A computer controlled syringe-type insulin infusion pump storing up to 254 different infusion rates, eight different meal programs and two different basal rates automatically changeable during 24 h in EPROM was used for insulin infusion applying a wavy step profile. This profile approaching the physiological postprandial insulin secretion of the B-cell was calculated by an algorithm following the biphasic insulin secretion model proposed by E. Cerasi . The computer program for the open loop infusion device simulated the feed-back structure of a closed loop insulin secretion control by an algorithm based upon a theoretical postprandial blood sugar profile. Fifteen unstable juvenile onset insulin requiring diabetics could be well controlled after two to three days of an intravenous open loop insulin infusion program. The programs consisted of two constant basal rates and superimposed wavy step profile programs activated at the beginning of each meal. The preabsorptive bolus or cephalic phase was an additional tool both for improved postprandial blood sugar control and further reduction of insulin consumption. The programmable insulin infusion device proved as a valuable tool for the study of a sophisticated insulin infusion profile suitable as well for open loop as for closed loop insulin infusion systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)

OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...

متن کامل

The Effect of Green Tea versus Sour Tea on Insulin Resistance, Lipids Profiles and Oxidative Stress in Patients with Type 2 Diabetes Mellitus: A Randomized Clinical Trial

Background: By decreasing oxidative stress and whereby decreasing insulin resistance, it may be possible to decrease complications of Diabetes Mellitus (DM). Green tea and sour tea contain phytochemicals which have anti-oxidative function. The aim of this study is to compare the effect of sour and green tea consumption on insulin resistance and oxidative stress in DM.Methods: This study is a ra...

متن کامل

Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience.

BACKGROUND Recent progress in the development of clinically accurate continuous glucose monitors (CGMs), automated continuous insulin infusion pumps, and control algorithms for calculating insulin doses from CGM data have enabled the development of prototypes of subcutaneous closed-loop systems for controlling blood glucose (BG) levels in type 1 diabetes. The use of a new personalized model pre...

متن کامل

The effects of short term intravenous infusion of a soybean based lipid emulsion on some blood constituents in sheep: A preliminary study

To evaluate the effect of intravenous infusion of a soybean based lipid emulsion (Lipovenoes 10%) on some blood constituents in sheep, a replicated 2 × 2 Latin square design experiment was conducted in four clinically healthy ewes. Lipid emulsion (LE group) or normal saline (NS group) was infused intravenously at a rate of 0.025 mL kg-1 per min for 6 hr and the concentrations of bloo...

متن کامل

Developmental and application of insulin infusion profiles for therapy of type-I diabetics with portable insulin infusion systems.

We studied the insulin requirements of seven insulin-dependent diabetics applying a glucose controlled insulin infusion system. The data were transformed into individually programmed and rectangular profiles. The MAGE, a measure of blood sugar fluctuations, was significantly lower when individually programmed step profiles were used (P less than 0.005) than it was when rectangular profiles were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 1984