Patch Based Synthesis of Whole Head MR Images: Application To EPI Distortion Correction

نویسندگان

  • Snehashis Roy
  • Yi-Yu Chou
  • Amod Jog
  • John A. Butman
  • Dzung L. Pham
چکیده

Different magnetic resonance imaging pulse sequences are used to generate image contrasts based on physical properties of tissues, which provide different and often complementary information about them. Therefore multiple image contrasts are useful for multimodal analysis of medical images. Often, medical image processing algorithms are optimized for particular image contrasts. If a desirable contrast is unavailable, contrast synthesis (or modality synthesis) methods try to "synthesize" the unavailable constrasts from the available ones. Most of the recent image synthesis methods generate synthetic brain images, while whole head magnetic resonance (MR) images can also be useful for many applications. We propose an atlas based patch matching algorithm to synthesize T2-w whole head (including brain, skull, eyes etc) images from T1-w images for the purpose of distortion correction of diffusion weighted MR images. The geometric distortion in diffusion MR images due to in-homogeneous B0 magnetic field are often corrected by non-linearly registering the corresponding b = 0 image with zero diffusion gradient to an undistorted T2-w image. We show that our synthetic T2-w images can be used as a template in absence of a real T2-w image. Our patch based method requires multiple atlases with T1 and T2 to be registeLowRes to a given target T1. Then for every patch on the target, multiple similar looking matching patches are found on the atlas T1 images and corresponding patches on the atlas T2 images are combined to generate a synthetic T2 of the target. We experimented on image data obtained from 44 patients with traumatic brain injury (TBI), and showed that our synthesized T2 images produce more accurate distortion correction than a state-of-the-art registration based image synthesis method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Assessment and improvement of fMRI normalization based on inversion-recovery prepared high-resolution EPI

Introduction Echo-planar imaging (EPI), used in most functional MRI (fMRI) studies, has several major limitations, including 1) geometric distortion, 2) low spatial-resolution, and 3) low anatomic resolvability, as compared with structural MRI data. Because of these limitations, it is difficult to accurately register EPI based fMRI data to structural images. For the same reasons, it remains cha...

متن کامل

Combined Prospective Rigid-Body Motion Correction with Retrospective Non-Rigid Distortion Correction for EPI

Introduction: Prospective real-time motion correction, where the scan-plane orientation is dynamically updated to track with the subject's head during an MRI scan, is becoming increasingly popular (1-7). While these methods focus on compensating for bulk rigid-body motion, a secondary effect of head motion is non-rigid-body image distortion caused by changes in the effective shim within the bra...

متن کامل

Image distortion correction in fMRI: A quantitative evaluation.

A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Simulation and synthesis in medical imaging : first International Workshop, SASHIMI 2016, held in conjunction with MICCAI 2016, Athens, Greece, October 21, 2016, Proceedings. SASHIMI (Workshop)

دوره 9968  شماره 

صفحات  -

تاریخ انتشار 2016