A method for the determination of proximal pulmonary vein size using contrast-enhanced magnetic resonance angiography.
نویسندگان
چکیده
OBJECTIVES We sought to develop a reproducible method for characterizing the anatomy of the proximal pulmonary veins. BACKGROUND Contrast-enhanced three-dimensional magnetic resonance angiography (CE-MRA) is a commonly requested test before and after radiofrequency ablation for the treatment of atrial fibrillation. While CE-MRA readily visualizes the pulmonary veins, there is no standardized method for determining their size and cross-sectional anatomy. METHODS Data for 24 consecutive patients referred for pulmonary vein CE-MRA before an elective ablation procedure for the treatment of atrial fibrillation were analyzed. Detailed measurements of the pulmonary vein diameter, circumference, and cross-sectional area were obtained at three locations: the juncture of the pulmonary vein with the left atrium (LA) (position 1J), the narrowest segment within 5 mm of the juncture (position 2(5mm)), and at the location in the sagittal plane at which the pulmonary veins separate from the LA and from each other (position 3Sag). Intraobserver and interobserver variabilities were also determined for each method. RESULTS The left lower pulmonary vein was significantly smaller than the other pulmonary veins at positions 1J and 2(5mm) (p<0.05). The right upper pulmonary vein was significantly larger than the other pulmonary vein at position 3Sag (p<0.05). At positions 1J and 2(5mm), the diameter had a low correlation with the circumference and cross-sectional area. At position 3Sag, the major and minor axis dimensions had a very high correlation with the circumference and cross-sectional area. The intraobserver and interobserver variabilities were substantially lower (better) for position 3Sag. CONCLUSIONS Pulmonary vein diameter measurements are highly variable and do not reflect true anatomic variation in cross-sectional anatomy. A sagittal method of determining pulmonary vein size was highly reproducible and may therefore be advantageous for use in patients likely to need serial examinations.
منابع مشابه
Contrast-enhanced MRA and 3D visualization of pulmonary venous anatomy to assist radiofrequency catheter ablation.
In pulmonary vein isolation as a treatment for atrial fibrillation the proximal part of the pulmonary veins is catheterized. A protocol for preinterventional assessment of pulmonary vein anatomy was developed, based on contrast-enhanced magnetic resonance angiography (MRA) in combination with three-dimensional visualization to tailor periprocedural angiography. The results allow for assessment ...
متن کاملNon–contrast-enhanced magnetic resonance angiography using time-spatial labeling inversion pulse technique for differentiation between pulmonary varix and arteriovenous malformation
Pulmonary varix is a rare entity that presents as a focal aneurysmal dilatation of the pulmonary vein and is frequently mistaken for a pulmonary arteriovenous malformation (PAVM). It is important to distinguish between pulmonary varix and PAVM because the former does not usually require treatment. We present the findings of non-contrast-enhanced magnetic resonance angiography with the time-spat...
متن کاملPulmonary vein imaging: comparison of 3D magnetic resonance angiography with 2D cine MRI for characterizing anatomy and size.
Pulmonary vein imaging is integral for planning atrial fibrillation ablation procedures. We tested the feasibility of quantifying pulmonary vein ostial diameter using two-dimensional cine cardiac magnetic resonance (2D cine CMR) and three-dimensional magnetic resonance angiography (3D MRA). Nine patients with a history of atrial fibrillation and 20 normal volunteers underwent 2D cine CMR and co...
متن کاملTime-resolved mr venography pre catheter-based ablation for atrial fibrillation
Objective The purpose of this study was to evaluate Time-resolved MR venography (TR-MRV) of the pulmonary venous circulation using the time-resolved angiography with interleaved stochastic trajectories (TWIST) method of time-resolved MRA (TR-MRA) and compare it with the more commonly used conventional Contrast enhanced magnetic resonance angiography (CE-MRA) approach in atrial fibrillation pati...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 6 4 شماره
صفحات -
تاریخ انتشار 2004