Initial evaluation of intrafraction motion using frameless CyberKnife VSI system.

نویسندگان

  • Alejandro Floriano
  • Icíar Santa-Olalla
  • Alberto Sanchez-Reyes
چکیده

AIM To analyze intrafraction movement in patients undergoing frameless robotic radiosurgery and evaluate the influence of image acquisition frequency on global accuracy. BACKGROUND Stereotactic radiosurgery requires high spatial accuracy in dose delivery. In conventional radiosurgery, a rigid frame is used to guarantee a correct target alignment and no subsequent movement. Frameless radiosurgery with thermoplastic mask for immobilization cannot completely eliminate intrafraction patient movement. In such cases, it is necessary to evaluate its influence on global treatment accuracy. MATERIALS AND METHODS We analyzed the intrafraction motion of the first 15 patients undergoing intracranial radiosurgery (39 fractions) with the CyberKnife VSI system at our institution. Patient position was measured at a 15-90-s interval and was used to estimate intrafraction patient movement. RESULTS With our acquisition image protocol and immobilization device, the 99% displacement error was lower than 0.85 mm. The systematic movement components were lower than 0.05 mm and the random component was lower than 0.3 mm in the 3 translational axes. Clear linear time dependence was found in the random component. CONCLUSIONS Selection of the X-ray image acquisition time is necessary to meet the accuracy required for radiosurgery procedures with the CyberKnife VSI system. We verified that our image acquisition protocol met the 1-mm criterion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of intrafraction motion and overall geometric accuracy of a frameless intracranial radiosurgery process

We conducted a comprehensive evaluation of the clinical accuracy of an image-guided frameless intracranial radiosurgery system. All links in the process chain were tested. Using healthy volunteers, we evaluated a novel method to prospectively quantify the range of target motion for optimal determination of the planning target volume (PTV) margin. The overall system isocentric accuracy was teste...

متن کامل

CyberKnife in the treatment of prostate cancer: a revolutionary system.

The CyberKnife is a frameless advanced robotic system that uses image-guided radiotherapy (IGRT) and adaptive radiotherapy (ART) for stereotactic radiosurgery technique in intraand extracranial lesions. The CyberKnife has also revolutionised the use of radiosurgery to treat tumours in different parts of the body. This system represents, after three-dimensional conformal radiotherapy (3DCRT), a ...

متن کامل

Intrafraction prostate translations and rotations during hypofractionated robotic radiation surgery: dosimetric impact of correction strategies and margins.

PURPOSE To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. METHODS AND MATERIALS A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strat...

متن کامل

Cyberknife radiotherapy for vestibular schwannoma.

Stereotactic radiosurgery is a well-established treatment modality for vestibular schwannoma. Initial reports using single-stage radiosurgery have demonstrated excellent tumor control rates. Many patients now elect to undergo radiosurgery given the potential for tumor control while avoiding the morbidity associated with microsurgical resection. In attempt to improve hearing preservation rates o...

متن کامل

Evaluation of inter- and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system.

PURPOSE To investigate prostatic organ motion at both setup and intrafraction using an onboard image-guided system. An intrafraction field-based repositioning method also was evaluated. MATERIALS AND METHODS A dual fluoroscopy with amorphous-silicon flat panel (DFFP) system was used for the three-dimensional registration of implanted markers in the prostate of eight organ-confined cancer pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2013