Inflammatory and metabolic response of the myocardium during aortic valve surgery on the beating heart.

نویسندگان

  • Mirsad Kacila
  • Stefano Bevilaqua
  • Sasha Matteucci
  • Marco Solinas
  • Andrea Farnetti
  • Gianetti Jacopo
  • Mattia Glauber
چکیده

This study has been conducted in an effort to establish metabolic and inflammatory responses of the myocardium during aortic valve surgery on the beating heart with CPB and continuous coronary sinus perfusion with normothermic blood. Twenty patients, divided into two groups, participated in this study. Conventional aortic valvular operations were performed on first 10 patients, while the second group, consisting of 10 patients as well, was subjected to the operations with CPB on the beating heart with continuously perfusion with blood through coronary sinus. There were total of 14 biological and 6 mechanical valves implanted in aortic position. In this study, cardiac markers and inflammatory mediators IL-8 and TNF, were measured preoperatively and postoperatively. Metabolic changes were documented based on the levels of CK-MB, troponin I, myoglobin and LDH. Inflammatory factors we measured through IL-8 and TNF. All measurements were taken in 6 hour intervals during the initial 48 hours following the operations. The patients of "the beating heart" group had significantly lower dose of markers and cytokines in comparison to those who had undergone the conventional valvular operation. The elimination of the adverse effects of global ischemia produced from reperfusion injury and the similarity to the physiological condition, suggests that the revival of the beating heart procedure is more reasonable. This procedure of valvular surgery on the beating heart can be one of the good surgical options for the high-risk valvular patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery

Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...

متن کامل

Use of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery

Introduction:  The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

بررسی 290 کودک مبتلا به بیماری دریچه‌ای قلبی روماتیسمی

    Background & Aim: Acute rheumatic fever and its cardiac involvement is one of the most prevalent acquired pediatric heart diseases in developing countries needing long hospitalization, cardiac surgery, prophylaxis, and delicate management and causing death in some cases. A paucity of information about this disease in our country made us perform the present study in one of the largest pediat...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bosnian journal of basic medical sciences

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2006