Mycotic Aneurysm in Thoracic Aorta Detected by Gallium-67 Scan: A Case Report

نویسندگان

  • Chi-Lin Kuo
  • Feng-Ju Chuang
  • Chung-Huei Hsu
  • Yuarn-Jang Lee
  • Chi-Ming Lee
  • Nen-Chung Chang
چکیده

Received 7/5/2002; revised 8/7/2002; accepted 8/19/2002. For correspondence or reprints contact: Chung-Huei Hsu, M.D., Department of Nuclear Medicine, Taipei Medical University Hospital, 252 Wu-Hsing Street, Taipei 110, Taiwan, R.O.C. Tel: (886)2-27395748, Fax: (886)2-27395749, E-mail: [email protected] Gallium-67 (Ga) citrate has been used for detecting infection and inflammation ever since its discovery in 1971. At the sites of inflammation, it is taken by leukocytes and bacterial siderophores. It has an affinity to lactoferrin which is released from degranulated neutrophils. To our knowledge, mycotic aneurym detected by Ga scan has rarely been reported. We report an interesting case of infected aneurysm of thoracic aorta detected by Ga citrate scan but was indeterminate on the MRI study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mycotic aortic aneurysm as a postsurgical complication: report of a case and review of the literature

Mycotic aneurysms are localized and irreversible dilatations of the arteries caused by weakening and damaging the arterial wall by an invasive organism establishing infective arteritis. Mycotic aneurysm of the thoracic aorta is a rare event; however, it can be fatal if not diagnosed early or not treated appropriately. Clinical findings are usually nonspecific; however, c...

متن کامل

SPECT/CT for the accurate localization of 67Ga uptake in mycotic abdominal aortic aneurysm

We report a case of mycotic abdominal aortic aneurysm where the use of hybrid imaging with gallium scan demonstrated increased uptake in the infected aneurysm and aided in differentiating physiological uptake in the bowel from pathological uptake.

متن کامل

BULL ET-INDUCED FALSE ANEURYSM OF THORACIC AORTA WITH A TEN YEAR LATENCY PERIOD IN A VICTIM OF THE IRAN-IRAQ WAR: REPORT OF A CASE

Traumatic false aneurysm of the thoracic aorta is not uncommon. But accordingly this case is unusual in its ten year delay between injury and presentation and treatment. A victim of the Iran-Iraq war is presented with a false aneurysm of the thoracic aorta ten years after a bullet injury to the chest and thoracic spine. Penetrating chest wounds, mechanisms of injury and diagnosis are also ...

متن کامل

Homograft replacement of thoraco-abdominal aorta for a leaking mycotic aneurysm.

We report the case of a 67-year-old, diabetic patient who underwent antibiotic-preserved homograft replacement of a thoraco-abdominal segment of the aorta for leaking mycotic aneurysm. This was successful in eradicating the sepsis and no graft complication had occurred at (18 months). Follow-up with computed tomography (CT) scanning.

متن کامل

99mTc-RBC scan in evaluation of mycotic aneurysm [Persian]

Mycotic aneurysm is an uncommon but very important complication of subacute infectious endocarditis. It is usually asymptomatic but often causes sudden and massive bleeding with high mortality rate. 99mTc-RBC scan is a noninvasive method for detection of mycotic aneurysm throughout the body. In this report two cases with mycotic aneurysm are presented and the usefulness of 99mTc-RBC scan ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002