Ion Chromatography (IC) ICP-MS forChromium Speciation in Natural Samples
نویسنده
چکیده
Trace measurements of the element chromium (Cr) are of interest in a wide range of applications and matrices. In the environment, Cr exists in two different oxidation states, the trivalent Cr(III) cation and hexavalent Cr(VI) anion. In mammals, Cr(III) is an essential element involved in the regulation of glucose; however, the element in its hexavalent form demonstrates mutagenic and carcinogenic effects at relatively low levels. Because of this duality, total Cr measurements do not provide sufficient information to establish potential toxicity. In order to assess the potential toxicity of the Cr level in a sample, it is the Cr(VI) concentration that must be measured, rather than the total Cr concentration. A new method was developed to couple Ion Chromatography to Octopole Reaction Cell ICP-MS (inductively coupled plasma mass Ion Chromatography (IC) ICP-MS for Chromium Speciation in Natural Samples Application spectrometry), to give a simple and reliable method for the separation and measurement of Cr(III) and Cr(VI), and so provide an accurate indication of the toxicity of the Cr level in a sample. This method has the merit of being applicable to high matrix samples, such as hard drinking water, due to the optimization of the sample preparation method and the chromatography. Also, the ICP-MS method provides excellent signal to noise, as a result of the removal of potentially interfering background species in the reaction cell, allowing the accurate determination of toxicologically useful levels of Cr(VI), at concentrations below 0.1 μg/L.
منابع مشابه
Determination of Organic and Inorganic Selenium Species Using HPLC-ICP-MS Application
A methodology based on coupling isocratic high-performance liquid chromatography (HPLC) and inductively coupled plasma mass spectrometry (ICP-MS) with optimized collision/reaction cell conditions has been developed for the simultaneous analysis of organic and inorganic selenium species in natural water samples. Selenium concentrations found in total and speciation analysis of a number of water ...
متن کاملIon chromatography–inductively coupled plasma mass spectrometry determination of arsenic species in marine samples
Arsenic speciation analysis in marine samples was performed using ion chromatography (IC) with inductively coupled plasma mass spectrometry (ICP-MS) detection. The separation of eight arsenic species, viz. arsenite, monomethyl arsonic acid, dimethylarsinic acid, arsenate, arsenobetaine, tetramethylarsine oxide, arsenocholine and tetramethylarsonium ion was achieved on a Dionex AS4A (weaker anio...
متن کاملDevelopment and application of a robust speciation method for determination of six arsenic compounds present in human urine.
Six arsenic species [arsenate, arsenite, arsenocholine, arsenobetaine, monomethyl arsonic acid, and dimethyl arsinic acid] present in human urine were determined using ion-exchange chromatography combined with inductively coupled plasma mass spectrometry (IC-ICP-MS). Baseline separation was achieved for all six species as well as for the internal standard (potassium hexahydroxy antimonate V) in...
متن کاملSelective arsenic speciation analysis of human urine reference materials using gradient elution ion-exchange HPLC-ICP-MS
Arsenic speciation analysis was performed in two human urine certified reference materials (NIES No. 18 and NIST SRM2670a) and three human urine control materials (Seronorm, Medisafe and Lyphocheck). The samples were diluted 1 1 3 prior to analysis by gradient elution anion or cation exchange high-performance liquid chromatography (HPLC) coupled with inductively coupled plasma mass spectrometry...
متن کاملHigh-performance liquid chromatography of selenoamino acids and organo selenium compounds. Speciation by inductively coupled plasma mass spectrometry.
As part of an ongoing study to identify selenium compounds with cancer chemopreventive activity, extracts of selenium-enriched samples were analyzed by HPLC-inductively coupled plasma (ICP)-MS. Ion-exchange, ion pair and derivatization methods for reversed-phase HPLC were considered and advantages and disadvantages for each compared. Anion exchange allows separation of selenite and selenate, bu...
متن کامل