Optimal Location for Shunt Connected FACTS Devices in a Series Compensated Long Transmission Line

نویسندگان

  • P. R. SHARMA
  • Ashok KUMAR
  • Narender KUMAR
چکیده

Shunt FACTS devices are used for controlling transmission voltage, power flow, reducing reactive losses, and damping of power system oscillations for high power transfer levels. In this paper the optimal location of a shunt FACT device is investigated for an actual line model of a transmission line having series compensation at the center. Effect of change in degree of series compensation on the optimal location of the shunt FACTS device to get the highest possible benefit is studied. It is found that the optimal location of the shunt FACTS device varies with the change in the level of series compensation to get the maximum benefit in terms of power transfer capability and stability of the system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Placement of shunt FACTS Devices for maximum power transfer capability in a Series Compensated LT Line

Maximum power transfer capability in the transmission line is the utmost important consideration in power systems. VAR Compensator (SVC) and Static Synchronous Compensator (STATCOM) are important devices in FACTS family, and is widely recognized as an effective and economical means to solve the power system stability problem. SVC and STATCOM are used as shunt in transmission system. In the pres...

متن کامل

Optimal Location and Parameter Settings of UPFC Device in Transmission System based on Imperialistic Competitive Algorithm

In this paper, we present a new method to determine the optimal location and parameter settings of UnifiedPower Flow Controller (UPFC) for removing voltage violations and transmission lines overloading. UPFC isconsidered as the most powerful member of the FACTS devices, that it can control shunt and series power flow.This option gives to UPFC the power to control the voltage profile and transmi...

متن کامل

Deciding optimal location for placing FACTS devices [UPFC, IPQC, DPFC] using Bang-Bang control technique

There are many problems arising in the electrical networks. In that, voltage fluctuation and power loss reduction becomes a major drawback in the electrical power supply system. Hence it is necessary to enhance the system power flow by placing suitable facts devices. The placement of FACTS devices in suitable location can lead to control the flow of current and maintain bus voltages in desired ...

متن کامل

Analyzing Impacts of FACTS Devices in Dealing with Short-Term and Long-Term Wind Turbine Faults

More than one hundred countries are using wind energy due to their easy implementation, cheap energy, and high energy efficiency. Implementation of FACTS devices in Wind Energy Conversion Systems (WECS) has been dramatically improved due to cooperative and accurate performance of FACTS devices. However, dealing with wind turbine faults promptly is crucial. Short-term and long-term faults may ha...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007