Evaluation of a software system for estimating planned dose error in patients, based on planar IMRT QA measurements
نویسندگان
چکیده
BACKGROUND Intensity modulated radiation therapy (IMRT) dosimetry verification is routinely conducted via integrated or individual field dosimetry using film or a matrix of detectors. Techniques and software systems are commercially available which use individual field dosimetry measurements as input into algorithms that estimate 3D patient dose distributions on CT scan derived target volumes and organs at risk (OARs), thus allowing direct dose-volume histogram (DVH) analysis vs. treatment planning system (TPS) DVH. The purpose of this work is to present a systematic benchmarking technique to evaluate the accuracy and consistency of such a software system. METHODS A MapCheck2 diode array and 3DVH™ software from Sun Nuclear were used for this study. Delivered planar dose was measured with the diode array as an input to 3DVH™ software that was used to estimate the 3D dose matrix. Accuracy of the output of 3DVH™ is tested by comparing measured planar doses over a range of depths to the same planes reconstructed by 3DVH™. Different fields from complex IMRT cases were selected and examined in this study. The sensitivity to depth of measurement was evaluated. RESULTS The Gamma Index analysis, comparing calculated 3D dose with measured 3D dose with 2% and 2mm distance-to-agreement (DTA) criteria returned a pass rate of > 90% for all patient cases calculated by the treatment planning system and it returned a pass rate of > 96% in 9 out of 10 cases calculated by 3DVH™. Extracted computed dose planes with 3DVH™ software at different depths in the flat phantom passed all gamma evaluation analyses when compared to measured planes at different depths using MapCheck2. CONCLUSIONS Studying complex head and neck IMRT fields, it was shown that the 3D dose distribution predicted by the planned dose perturbation (PDP) algorithm is both accurate and consistent.
منابع مشابه
Characterization and clinical evaluation of a novel IMRT quality assurance system
Intensity-modulated radiation therapy (IMRT) is a complex procedure that involves the delivery of complex intensity patterns from various gantry angles. Due to the complexity of the treatment plans, the standard-of-care is to perform measurement based patient-specific quality assurance (QA). IMRT QA is traditionally done with film for relative dose in a plane and an ion chamber for absolute dos...
متن کاملQA of intensity-modulated beams using dynamic MLC log files
To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Varian, Clinac DMX linear accelerator. To measure planar dose distribution, Kodak, EDR2 films are e...
متن کاملCurtailing patient-specific IMRT QA procedures from 2D dose error distribution
A patient-specific quality assurance (QA) test is conducted to verify the accuracy of dose delivery. It generally consists of three verification processes: the absolute point dose difference, the planar dose differences at each gantry angle, and the planar dose differences by 3D composite irradiation. However, this imposes a substantial workload on medical physicists. The objective of this stud...
متن کاملInverse Verification of the Dose Distribution for Intensity Modulated Radiation Therapy Patient-specific Quality Assurance Using Dynamic MLC Log Files
The aim of this study was to investigate a novel method for verification of the dose distribution for intensity modulated radiation therapy (IMRT) patient-specific quality assurance (QA) using dynamic multi-leaf collimator (DMLC) log files (Dynalog files). Dynalog files are recorded every 50 ms by using a MLC controller during the IMRT treatment. Dynalog files contain actual MLC positional info...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کامل