Soft liner-retained, implant-supported overdenture: a technical note.

نویسندگان

  • J R Cain
  • D L Mitchell
چکیده

This paper describes the design and fabrication of a soft liner-retained, implant-supported overdenture used in 10 patients over a period of 1 to 6 years. A final complete denture impression is made of the dental arch, including implant abutments extending 5 mm above the gingival tissue. The master cast is fabricated with actual abutments placed in the impression. After the final wax try-in, the denture is flasked in the usual manner with the metal abutments in place. Before packing with acrylic resin, plastic tubing 1 to 2 mm thick is placed around each abutment. The denture is trial packed and allowed to bench cure over night. The plastic tubing is then removed and a soft denture lining material is placed in these areas only. The flask is closed and cured according to the manufacturer's recommendation. The denture is delivered as a conventional overdenture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of two different soft liners and thicknesses mediating stress transfer for immediately loaded 2-implant supported mandibular overdentures: A finite element analysis study.

STATEMENT OF PROBLEM The use of soft liners as female receptacles for ball attachments retaining immediately loaded implant overdenture has been recommended to enhance osseointegration and provide a shock absorbing effect. However, which liner and which thickness is still unclear. PURPOSE The purpose of this finite element analysis (FEA) study was to evaluate the effect of a 2- and 4-mm thick...

متن کامل

Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview

This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant pr...

متن کامل

Fabricating a Soft Liner-Retained Implant-Supported Palatal Lift Prosthesis for an Edentulous Patient: A Case Report

This case report describes fabrication of a palatal lift prosthesis for a quadriplegic edentulous 30-year-old male with past head traumatic injury. We constructed an implant supported bar and used a soft-lining material for the maxillary palatal lift prosthesis to minimize the possibility of implant overloading and also provide a less complex and less expensive procedure for this patient.

متن کامل

Early Loaded Single Implant Reinforced Mandibular Overdenture

Rehabilitating atrophied mandible with two-implant supported denture is a common treatment modality for implant retained removable overdenture in mandible. This paper aims to design a treatment modality where single implant reinforced overdenture is fabricated for a severely atrophied mandibular ridge with early loading protocol. Results of studies have shown that a single implant mandibular ov...

متن کامل

Tooth and implant supported over denture : a case report

Corresponding author:Dr. AvneetKaur,Department of Prosthodontics, Mahatma Gandhi Medical College and Hospital Jaipur. This article may be cited as:Kaur A, Padiyar N Kaurani P and Meena S Tooth and implant supported over denture: a case report2017;3(2):33-36 Article Received: 08-02-17 Accepted On: 23-02-2017 NTRODUCTION Overdenture treatment uses a removable complete denture that overlies retain...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 13 6  شماره 

صفحات  -

تاریخ انتشار 1998