Automatically Detecting Rotation in Chest Radiographs Using Principal Rib-Orientation Measure for Quality Control
نویسندگان
چکیده
Abstract. We present a novel method for detecting rotated lungs in chest radiographs for quality control and augmenting automated abnormality detection. The method computes a principal rib-orientation measure using a generalized line histogram technique for quality control, and therefore augmenting automated abnormality detection. To compute the line histogram, we use line seed filters as kernels to convolve with edge images, and extract a set of lines from the posterior rib-cage. After convolving kernels in all possible orientations in the range [0◦, 180◦), we measure the angle with maximum magnitude in the line histogram. This measure provides an approximation of the principal chest rib-orientation for each lung. A chest radiograph is upright if the difference between the orientation angles of both lungs with respect to the horizontal axis is negligible. We validate our method on sets of normal and abnormal images and argue that rib orientation can be used for rotation detection in chest radiographs as an aid in quality control during image acquisition. It can also be used for training and testing data sets for computer aided diagnosis research, for example. In our experiments, we achieve a maximum accuracy of approximately 90%.
منابع مشابه
A segmental radiological study of the spine and rib – cage in children with progressive Infantile Idiopathic Scoliosis
BACKGROUND The role of rib cage in the development of progressive infantile idiopathic scoliosis (IIS) has not been studied previously. No report was found for rib growth in children with IIS. These findings caused us to undertake a segmental radiological study of the spine and rib-cage in children with progressive IIS. The aim of the present study is to present a new method for assessing the t...
متن کاملA nonparametric-based rib suppression method for chest radiographs
This paper presents an automated and comprehensive system for eliminating rib shadows in chest radiographs, which integrates lung field identification, rib segmentation, rib intensity estimation, and suppression. We designed a region of interest (ROI)-based method to estimate a suitable initial lung boundary for active shape model (ASM) deformation by determining the translation and scaling par...
متن کاملAutomatic Detection Of Rib Contours in Chest Radiographs
We have constructed a computer algorithm that finds the contours of the dorsal and ventral portions of the images of ribs in chest radiographs. The following are a few of the expected uses for the automatic detection of rib contours: 1. Rib images contribute false positives in tumor-detection algorithms. Hence> detecting the rib contours should f a c i l i t a t e removal of these lalse posltiv...
متن کاملReliability study for rib index
Objectives The Rib Index, (RI), extracted from the double rib couture sign (DRCS) on lateral spinal radiographs to evaluate rib hump deformity in IS patients has been earlier introduced (Grivas at al 2000). Although various papers using the RI have been published, no study of its reproducibility was reported. To estimate the variations of the RI in a number of a pair set of lateral chest radiog...
متن کاملTemporal subtraction of chest radiographs compensating pose differences
Temporal subtraction techniques using 2D image registration improve the detectability of interval changes from chest radiographs. Although such methods are well known for some time they are not widely used in radiologic practice. The reason are strong pose differences between these follow-up acquisitions with a time interval of months to years in between. Such strong perspective differences occ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IJPRAI
دوره 29 شماره
صفحات -
تاریخ انتشار 2015