Corneal topographic astigmatism (CorT) to quantify total corneal astigmatism.
نویسندگان
چکیده
PURPOSE To evaluate the performance of corneal topographic astigmatism (CorT) based on total corneal power measurements. METHODS Anterior, posterior, and total corneal power measurements of 526 virgin eyes obtained using the CSO Sirius tomographer (Costuzione Strumenti Oftalmici, Scandicci, Florence, Italy) were analyzed. Individual CorTs were created from each set of data. These CorTs were assessed using ocular residual astigmatism (ORA), which quantifies corneo-refractive differences. A low standard deviation of the ocular residual astigmatism (ORAsd) indicates a low variability between corneal astigmatism and refractive cylinder. A low mean of the ORA magnitude indicates a close correlation of refractive cylinder and corneal astigmatism. RESULTS The CorT based on total corneal power measurements had an ORAsd of 0.30 diopters (D) and a mean ORA magnitude of 0.53 D. The CorT candidates based on anterior corneal power measurements all had an ORAsd of at least 0.32 D, and the mean ORA magnitudes were all 0.64 D or greater. Both the ORAsd and mean ORA magnitude of the CorT based on total corneal power measurements were significantly less than those of the CorT based on anterior corneal power measurements (both P < .001, as estimated via bootstrapping). CONCLUSIONS The CorT based on total corneal power measurements corresponds better, both in variability and closeness, with manifest refractive cylinder than the CorT based on anterior corneal power measurements. This total CorT would be fundamental when planning toric intraocular lenses or limbal relaxing incisions or other corneal astigmatic surgery.
منابع مشابه
New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder.
PURPOSE To derive a method of quantifying corneal topographic astigmatism (CorT) that accurately represents manifest refractive cylinder. SETTING Private practice, Melbourne, Australia. DESIGN Retrospective study. METHOD Axial power measurements obtained using topography in right eyes and left eyes were analyzed. For each Placido ring, an astigmatism value was calculated. The ring astigma...
متن کاملهمبستگی آستیگماتیسم رفرکتیو، قرنیهای و لنتیکولار در افراد داوطلب جراحی رفرکتیو
Background and purpose: Astigmatism is a common optical dysfunction, effective on various visual outcomes and one of the important criteria of refractive surgery. The aim of present study was to evaluate the correlation between refractive, corneal and residual astigmatism in refractive surgery candidates. Materials and methods: In this cross-sectional descriptive, analytical study, 200 patient...
متن کاملSurgically Induced Astigmatism Assessment
The article “Surgically Induced Astigmatism Assessment: Comparison Between Three Corneal Measuring Devices” by Ofir et al.1 was effective in demonstrating equivalence between three anterior corneal measuring devices (Lenstar LS900, Haag-Streit, Koeniz, Switzerland; IOLMaster 500, Carl Zeiss Meditec, Dublin, CA; and Atlas topographer, Carl Zeiss Meditec) by assessing the vectorial astigmatism ch...
متن کاملCorneal topographic changes in a case of limbal conjunctival carcinoma.
PURPOSE To describe topographic changes in a case of limbal conjunctival carcinoma. METHODS Corneal topography was performed before and 3 months after excision. RESULTS Preoperative topography revealed a localized flattening (37.1 diopters [D]) adjacent to the tumor and extending to the corneal apex, causing a 3-diopter asymmetric with-the-rule astigmatism. Preoperative corneal curvature wa...
متن کاملEffects of chalazia on corneal astigmatism
BACKGROUND A chalazion is a common eyelid disease that causes eye morbidity due to inflammation and cosmetic disfigurement. Corneal topographic changes are important factors in corneal refractive surgery, intraocular lens power calculations for cataract surgery, and visual acuity assessments. However, the effects of chalazia on corneal astigmatism have not been thoroughly investigated. The chan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 31 3 شماره
صفحات -
تاریخ انتشار 2015