Comparison of Energy Use and Piglet Performance Between Conventional and Energy-Efficient Heat Lamps

نویسندگان

  • Hongwei Xin
  • Hongsen Zhou
  • Dwaine S. Bundy
چکیده

A one-year field study compared the conventional 250W IR heat lamp with an energy-efficient 175W radiant heat lamp for swine farrowing operations. The energy-efficient heat lamp showed a $36 annual cash savings per unit (assuming $0.10/kWh electricity); a 1.2% absolute reduction in piglet mortality from birth to weaning (5.0±0.28% vs. 6.2±0.44%) (P<0.01); a 45% lower lamp failure rate (18±4% vs. 32±3%) (P<0.05); and a slightly higher rate of weight gain for the piglets (217±4 g/day vs. 211±4 g/day) (P>0.05). The possible benefits of using the energy-efficient heat lamp include an annual energy savings of $5,400 and 284 more weaned pigs for a 1,000-sow farrowing operation. The study also revealed circadian patterns of thermoregulatory behavior of the piglets, i.e., higher heat lamp usage during the day and lower at night. Both the frequency and the magnitude of heat lamp usage seemed to depend on heat lamp size and piglet age. Particularly, piglets spent more time under the 175W heat lamp than under the 250W heat lamp, although visits to the heat lamps decreased with piglet age in both instances. The results suggest that to accommodate the progressively decreasing thermal needs of the piglets, a variable-output heat lamp would be more suitable than a constant-output heat lamp. Further research is warranted to quantify the dynamic thermal needs of the piglets during this critical phase of their life cycle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Economic optimization and comparative study of solar heat pumps

In this paper, an economic study of solar heat pumps and an investigation of differences between solar heat pumps and conventional heat pumps—based on their performances and energy consumption—are conducted for a residential apartment located in Austin, Texas, USA. Heating in the apartment is provided via a solar heat pump during the cold months of a year. Solar collectors are used to meet the ...

متن کامل

Comparison of heat loss and air infiltration through the openings of Qajar and Pahlavi era houses in Tabriz

The rapidly growing world energy use has already raised concerns over energy resources and greenhouse gas (GHG) emissions. Since the global contribution from residential buildings towards energy consumption, has steadily increased between 20% and 40% and as large openings have considerable energy and heat loss in dwellings, this paper establishes a coefficient of heat loss and air infiltration ...

متن کامل

Introduction to the Slide Modeling Method for the Efficient Solution of Heat Conduction Calculations

Determination of the maximum temperature and its location is the matter of the greatest importance in many technological and scientific engineering applications. In terms of numerical calculations of the heat conduction equation by using uniform mesh increments in space, large computational cost is sometimes countered. However, adaptive grid refinement method could be computationally efficient ...

متن کامل

Development of a Pilot Plant Solar Liquid Desiccant Air Conditioner for the Northern Region of Iran

In a 10-ton capacity pilot plant solar liquid desiccant air conditioner (LDAC) developed, dehumidification of the outside air is achieved through a honeycomb packed-bed heat and mass exchanger, using lithium chloride solution as the desiccant. The dry air obtained from the dehumidification process is evaporative cooled inside a cooling pad and directed into the conditioned space. The dilute sol...

متن کامل

Experimental and Numerical Investigations on Al2O3–Tricosane Based Heat Pipe Thermal Energy Storage

The enhancement of operating life cycle of electronic devices necessitates the development of efficient cooling techniques. Therefore, in the present work the effects of employment of Phase Change Material, in the adiabatic section of heat pipe for electronic cooling applications were experimentally and numerically investigated. Tricosane (100 ml) is chosen as PCM in this study, where Al2O3 nan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017