A Predictable Fixed Gain Instrumentation Amplifier

نویسندگان

  • Kang
  • Ning
چکیده

This paper presents a predictable fixed gain instrumentation amplifier using switched capacitor instead of resistor to improve the accuracy of the gain as 10. This instrumentation amplifier builds up by two operational amplifiers which connect by switched capacitor. These switched capacitors are used to stable the whole circuit, fix the gain of total instrumentation amplifier. Using two operational amplifiers can achieve high input impedance, high CMRR and wide input swing voltage. These two operational amplifiers should have different characteristics. The first sampling amplifier is mainly used to sample the signal and the second amplifier is mainly used to amplify the signal. Keywords—switched capacitor; instrumentation amplifier; fixed gain; CMRR; noise ; input impedance

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving Linearity of CMOS Variable-gain Amplifier Using Third-order Intermodulation Cancellation Mechanism and Intermodulation Distortion Sinking Techniques

This paper presents an improved linearity variable-gain amplifier (VGA) in 0.18-µm CMOS technology. The lineari­ty improvement is resulted from employing a new combinational technique, which utilizes third-order-intermodulation (IM3) cancellation mechanism using second-order-intermodul­ation (­IM2) injection, and intermodulation distortion (IMD) sinking techniques. The proposed VGA gain cell co...

متن کامل

Hardware approach to wireless EMG electrode realization

EWEE include following parts: GUARD and Driven-Right-Leg (DLR) systems [2, 3, 6]. First system protects wire connections (on PCB, silver contacts with differential amplifier) against electromagnetic influence. The second provides better Common Mode Rejection Rate (CMRR) coefficient in range of 20-50dB higher. Another parts of system are: silver contacts [5], instrumentation amplifier with perma...

متن کامل

Design of High CMRR Instrumentation Amplifier for Biomedical Systems

This paper describes an instrumentation amplifier (INA) with three operational amplifier (op amp) topology, for biomedical applications. To achieve low offset new circuit technique is achieved by adding NMOS transistor and two phase clock scheme with a frequency of 20 KHz. With the unity gain bandwidth of 92 KHz , the open loop gain of this instrumentation amplifier is found to be 50 dB and hav...

متن کامل

A CMOS Based Balanced Differential Amplifier with MOS Loads

The Balanced Differential Amplifiers play a most important role as basic building block in instrumentation amplifier circuit. One of the characteristic of a differential amplifier, the common mode rejection ratio (CMRR) is most important. The active load used for balanced differential amplifier is going to affect differential gain, thus CMRR of the circuit. The active load used can be a diode c...

متن کامل

High-accuracy instrumentation amplifier for low voltage low power CMOS smart sensors

In low voltage low power CMOS systems both the high input offset and noise voltages of MOSFETs and also the moderate gain of op amps limit the accuracy of analog circuits. In this paper we present a new high-accuracy instrumentation amplifier; this circuit topology is the first ever reported "non-autozero" instrumentation amplifier which allows to compensate, beside the input offset and noise v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014