The replacement correction factors for cylindrical chambers in high-energy photon beams.
نویسندگان
چکیده
The values of the replacement correction factors (P(repl), or in the IAEA's notation p(dis)p(cav)) used for cylindrical chambers in high-energy photon beams represent one of the most significant differences between the AAPM and the IAEA dosimetry protocols. In a previous study (Wang L L W and Rogers D W O 2008 Med. Phys. 35 1747-55), we found that the AAPM protocol adopted incorrect values of P(repl) for cylindrical chambers in photon beams. For a (60)Co beam, the calculated P(repl) value is 0.5% higher than the AAPM value and about 1% higher than the IAEA value. It was still not clear why the IAEA values, which are based on measurements by Johansson et al, are incorrect. In this study, EGSnrc Monte Carlo simulation codes are used to simulate Johansson et al's experimental procedures for determining P(repl) values. The simulation results agree well with the measurements if the chamber responses versus depth are normalized at d(max) as was apparently done in the experiments as it was believed that the chambers of different radii gave the same maximum reading at the respective d(max). However, if the chamber responses are not normalized, then the simulated experimental results lead to a result which agrees well with the P(repl) values calculated by the standard Monte Carlo methods. This demonstrates that the normalization procedure used in the experiments is incorrect as is based on an incorrect assumption, and thus the interpretation of Johansson et al's experimental values as P(repl) (p(dis)) in the IAEA TRS-398 Code of Practice is wrong. The values of P(repl) for cylindrical chambers of different radii in various high-energy photon beams are calculated and an empirical formula is given.
منابع مشابه
Effective Point of Measurement in Cylindrical Ion Chamber for Megavoltage Photon Beams
Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...
متن کاملMeasurements of output factors using different ionization chambers and build up caps
Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Com...
متن کاملEnergy Gain of Magnetized Cylindrical D-T Targets in Fast Ignition Fusion
In recent years, many different plans have been considered to use the nuclear energy gained from inertial confinement fusion (ICF) as attempts to obtain high energy efficiencies. In conventional ICF methods, a small amount (about mg) of the deuterium–tritium compound is confined in a small spherical chamber of a few millimeters in radius and compressed by laser or heavy ion beams with powers in...
متن کاملEnergy Gain of Magnetized Cylindrical D-T Targets in Fast Ignition Fusion
In recent years, many different plans have been considered to use the nuclear energy gained from inertial confinement fusion (ICF) as attempts to obtain high energy efficiencies. In conventional ICF methods, a small amount (about mg) of the deuterium–tritium compound is confined in a small spherical chamber of a few millimeters in radius and compressed by laser or heavy ion beams with powers in...
متن کاملDetermination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 54 6 شماره
صفحات -
تاریخ انتشار 2009